HFA240NJ40D

Reduced RFI and EMI
Reduced Snubbing
Extensive Characterization of
Recovery Parameters
Features
Description
HEXFRED
TM
diodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are
ideally suited for power converters, motors drives and other applications
where switching losses are significant portion of the total losses.
Ultrafast, Soft Recovery DiodeHEXFRED
TM
HFA240NJ40D
PD -2.512 rev. A 02/99
V
R
= 400V
V
F
(typ.) = 1V
I
F(AV)
= 240A
Q
rr
(typ.) = 290nC
I
RRM
(typ.)
= 7.5A
t
rr
(typ.)
= 50ns
di
(rec)M
/dt (typ.) = 270A/µs
TO-244AB
Thermal - Mechanical Characteristics
Absolute Maximum Ratings (per Leg)
lbfin
(Nm)
°C/W
K/W
Parameter Min. Typ. Max. Units
R
thJC
Junction-to-Case, Single Leg Conducting   0.27
Junction-to-Case, Both Legs Conducting   0.14
R
thCS
Case-to-Sink, Flat, Greased Surface  0.10 
Wt Weight  79 (2.8)  g (oz)
Mounting Torque 30 (3.4)  40 (4.6)
Mounting Torque Center Hole 12 (1.4)  18 (2.1)
Terminal Torque 30 (3.4)  40 (4.6)
Vertical Pull   80
2 inch Lever Pull   35
Parameter Max. Units
V
R
Cathode-to-Anode Voltage 400 V
I
F
@ T
C
= 25°C Continuous Forward Current 244
I
F
@ T
C
= 100°C Continuous Forward Current 122
I
FSM
Single Pulse Forward Current 900
E
AS
Non-Repetitive Avalanche Energy 1.4 mJ
P
D
@ T
C
= 25°C Maximum Power Dissipation 460
P
D
@ T
C
= 100°C Maximum Power Dissipation 185
T
J
Operating Junction and
T
STG
Storage Temperature Range
-55 to +150
W
A
C
lbfin
Note: Limited by junction temperature Mounting surface must be smooth, flat, free or burrs or other
L = 100µH, duty cycle limited by max T
J
protrusions. Apply a thin even film or thermal grease to mounting
125°C surface. Gradually tighten each mounting bolt in 5-10 lbfin steps
until desired or maximum torque limits are reached. Module
1
Anode Cathode
1 2
Base AC
HFA240NJ40D
PD-2.512 rev. A 02/99
2
63.50 (2.500)
60.96 (2.400)
23.55 (0.927)
20.42 (0.804)
14.99 (0.590)
15.75 (0.620)
20.32 (0.800)
17.78 (0.700)
39.75 (1.565)
40.26 (1.585)
80.01 (3.150)
34.925 (1.375)
3.35 (0.132)
3.02 (0.119)
90.17 (3.550)
92.71 (3.650)
DIA.
7.49 (0.295)
6.99 (0.275)
(2 PLCS.)
10.41 (0.410)
9.65 (0.380)
DIA.
DIA.
4.70 (0.185)
4.95 (0.195)
1/4-20 SLOTTED HEX
REF.
Dimensions in Millimeters and (Inches)
CONFORMS TO JEDEC
OUTLINE TO-244AB
1
2
3
LEAD ASSIGNMENTS
1 - ANODE
2 - CATHODE
3 - ANODE
Parameter Min. Typ. Max. Units Test Conditions
V
BR
Cathode Anode Breakdown Voltage 400   V I
R
= 100µA
V
FM
Max Forward Voltage  1.1 1.3 I
F
= 120A
 1.3 1.5 V I
F
= 240A See Fig. 1
 1.0 1.2 I
F
= 120A, T
J
= 125°C
I
RM
Max Reverse Leakage Current  1.5 9.0 µA V
R
= V
R
Rated
 2.3 12 mA T
J
= 125°C, V
R
= 320V
C
T
Junction Capacitance  280 380 pF V
R
= 200V See Fig. 3
From top of terminal hole to mounting
plane
Electrical Characteristics (per Leg) @ T
J
= 25°C (unless otherwise specified)
Dynamic Recovery Characteristics (per Leg) @ T
J
= 25°C (unless otherwise specified)
A/µs
nC
A
L
S
Series Inductance  6.0  nH
See Fig. 2
Parameter Min. Typ. Max. Units Test Conditions
t
rr
Reverse Recovery Time  50  I
F
= 1.0A, di
f
/dt = 200A/µs, V
R
= 30V
t
rr1
 77 120 ns T
J
= 25°C See Fig.
t
rr2
 290 440 T
J
= 125°C 5 I
F
= 120A
I
RRM1
Peak Recovery Current  7.5 14 T
J
= 25°C See Fig.
I
RRM2
 16 30 T
J
= 125°C 6 V
R
= 200V
Q
rr1
Reverse Recovery Charge  290 780 T
J
= 25°C See Fig.
Q
rr2
 2300 6300 T
J
= 125°C 7 di
f
/dt = 200A/µs
di
(rec)M
/dt1 Peak Rate of Fall of Recovery Current  320  T
J
= 25°C See Fig.
di
(rec)M
/dt2 During t
b
 270  T
J
= 125°C 8
HFA240NJ40D
PD-2.512 rev. A 02/99
3
Fig. 4 - Maximum Thermal Impedance Z
thJC
Characteristics, (per Leg)
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage, (per Leg)
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage, (per Leg)
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current,
(per Leg)
0.1
1
10
100
1000
10000
100000
0 100 200 300 400
R
R
Reverse Voltage - V (V)
T = 150°C
Reverse Current - I (µA)
T = 125°C
T = 25°C
J
J
J
100
1000
10000
1 10 100 1000
T = 25°C
J
Reverse Voltage - V (V)
R
T
Junction Capacitance - C (pF)
A
1
10
100
1000
0.4 0.8 1.2 1.6 2.0
FM
F
Instantaneous Forward Current - I (A)
Forward Voltage Drop - V (V)
T = 150°C
T = 125°C
T = 25°C
J
J
J
0.001
0.01
0.1
1
0.00001 0.0001 0.001 0.01 0.1 1 10
Notes:
1. Duty factor D = t / t
2. Peak T =P x Z + T
1 2
J DM thJC C
P
t
t
DM
1
2
t , Rectangular Pulse Duration (sec)
Thermal Response (Z )
1
thJC
0.01
0.02
0.05
0.10
0.20
D = 0.50
SINGLE PULSE
(THERMAL RESPONSE)

HFA240NJ40D

Mfr. #:
Manufacturer:
Vishay
Description:
DIODE MODULE 400V 244A TO244AB