G2AK
■ Contact Ratings
■ Characteristics
Note: 1. The data shown above are initial values.
2. The contact resistance was measured with 0.1 A at 5 VDC using the fall-of-potential method.
3. The set or reset time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C.
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
strength.
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute.
Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4) (L/R = 7 ms)
Contact type Crossbar bifurcated
Contact material Movable:Au-clad AgPd
Fixed:AgPd
Rated load 0.3 A at 110 VAC
0.5 A at 24 VDC
0.2 A at 110 VAC
0.3 A at 24 VDC
Rated carry current 3 A
Max. switching voltage 250 VAC, 125 VDC
Contact resistance (see note 2) 100 mΩ max.
Set time (see note 3) AC: 25 ms max.; DC: 15 ms max.
Reset time (see note 3) AC: 25 ms max.; DC: 15 ms max.
Min. pulse width AC: 50 ms; DC: 30 ms
Max. operating frequency Mechanical: 18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load)
Insulation resistance (see note 4) 100 MΩ min. (at 500 VDC)
Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between coil and contact (700 VAC between contacts of same pole)
(1,000 VAC between set and reset coils)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
(for contact malfunction);
3.0-mm double amplitude (for armature malfunction)
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
, 300 m/s
2
Endurance Mechanical: 100,000,000 operations min. (at operating frequency of 18,000 operations/hour)
Electrical: 5,000,000 operations min. (under rated load and at operating frequency of
1,800 operations/hour) (see note 5)
Error rate (level P)
(Reference value) (see note 6)
1 mA at 100 mVDC
Ambient temperature Operating:–10°C to 40°C (with no icing or condensation)
Ambient humidity Operating:5% to 85%
Weight Approx. 38 g
Method of Connection
• Reset side
DC coil: Connect terminal No. 13 to terminal No. 9 or No. 13 to No. 5.
AC coil: Connect terminal No. 13 to terminal No. 5.
• Set side
DC coil: Connect terminal No. 14 to terminal No. 12 or No. 14 to No. 8.
AC coil: Connect terminal No. 14 to terminal No. 8.
RESET SET
External
resistor for
reset coil
External
resistor for
set coil
13 14
− + − +
9
10
11
12
1234
5678