https://www.phoenixcontact.com/us/products/2901672
12/4/13Page2/3
PV string monitoring module-SCK-M-8S-20A-2901672
Technical data
Input data
Input current range 0 A ... 20 A
Overload capacity Depending on through connected conductor
Connection method Through connection, 10 mm diameter
Switching output
Output name No switching output
Power supply
Supply voltage range (Via SCK-C-MODBUS communication module)
Connection data
Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
General
Maximum transmission error < 1 % (of final value)
Test voltage 5.8 kV AC ((50 Hz/1 min))
Pollution degree 2
Rated insulation voltage 1200 V DC (Voltage input/output)
Standards/regulations EN 61010-1
Electromagnetic compatibility
Conformance with EMC directive 2004/108/EC and for low-voltage
directive 2006/95/EC
Mounting position any
Assembly instructions Horizontal or vertical
Torque 0.5 Nm ... 0.6 Nm
Classifications
eCl@ss
eCl@ss 4.0 27210902
eCl@ss 4.1 27371105
eCl@ss 5.0 27371801
eCl@ss 5.1 27210902
eCl@ss 6.0 27210902
eCl@ss 7.0 27210902