Ordering codes and packing units
V
R
V DC
V
RMS
f 60 Hz
V AC
C
R
µF
Max. dimensions
d × l
mm
Ordering code
(composition see
below)
Untaped
pcs./MOQ
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
630 200 0.033 7.4 × 18.5 B32537B8333+000 200
0.047 7.4 × 18.5 B32537B8473+000 200
0.068 8.4 × 21.0 B32537B8683+000 200
0.10 9.4 × 21.0 B32537B8104+000 80
0.15 9.4 × 21.0 B32537B8154+000 80
0.22 11.7 × 21.0 B32537B8224+000 80
0.33 12.7 × 21.0 B32537B8334+000 80
0.47 13.7 × 21.0 B32537B8474+000 80
0.68 12.7 × 34.0 B32537B8684+000 80
1.0 15.7 × 34.0 B32537B8105+000 80
1.5 17.7 × 34.0 B32537B8155+000 80
2.2 20.7 × 34.0 B32537B8225+000 80
3.3 25.7 × 34.0 B32537B8335+000 80
4.7 29.7 × 34.0 B32537B8475+000 80
B32537
High reliability (wound)
Page 6 of 20Please read Cautions and warnings and
Important notes at the end of this document.
Technical data
Operating temperature range Max. operating temperature T
op,max
+125 °C
Upper category temperature T
max
+100 °C
Lower category temperature T
min
55 °C
Rated temperature T
R
+85 °C
Dissipation factor tan δ (in 10
-3
) C
R
(µF) 0.47 0.47 < C
R
4.7 4.7 < C
R
10.0 > 10.0
at 20 °C
at 1 kHz 7 8 8 10
(upper limit values) at 10 kHz 15 22 25
Insulation resistance R
ins
C
R
or time constant τ = C
R
R
ins
0.33 µF > 15000 M
at 20 °C, rel. humidity 65% > 0.33 µF > 5000 s
(minimum as-delivered values)
DC test voltage 1.4 V
R
, 2 s
Category voltage V
C
T
A
(°C) DC voltage derating AC voltage derating
(continuous operation with V
DC
T
A
85 V
C
= V
R
V
C,RMS
= V
RMS
or V
AC
at f 60 Hz) 85<T
A
100 V
C
= V
R
(165T
A
)/80 V
C,RMS
=V
RMS
(165T
A
)/80
Operating voltage V
op
for
T
A
(°C) DC voltage (max. hours) AC voltage (max. hours)
short operating periods T
A
100 V
op
= 1.25 V
C
(2000 h) V
op
= 1.0 V
C,RMS
(2000 h)
(V
DC
or V
AC
at f 60 Hz) 100<T
A
125 V
op
= 0.5 V
R
(1000 h) V
op
= 0.5 V
RMS
(1000 h)
Damp heat test 56 days/40 °C/93% relative humidity
Limit values after damp Capacitance change C/C 5%
heat test Dissipation factor change tan δ 5 10
-3
(at 1 kHz)
Insulation resistance R
ins
50% of minimum
as-delivered values
Reliability:
Failure rate λ
1 fit (1 10
-9
/h) at 0.5 V
R
, 40 °C
Service life t
SL
200 000 h at 1.0 V
R
, 85 °C
For conversion to other operating conditions and temperatures,
refer to chapter "Quality, 2 Reliability".
Failure criteria:
Total failure Short circuit or open circuit
Failure due to variation Capacitance change C/C > 10%
of parameters Dissipation factor tan δ > 1.5 upper limit value
Insulation resistance R
ins
< 150 M(C
R
0.33 µF)
or time constant τ = C
R
R
ins
< 50 s (C
R
> 0.33 µF)
B32537
High reliability (wound)
Page 7 of 20Please read Cautions and warnings and
Important notes at the end of this document.
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Length of capacitor 18.5 mm 21 mm 34 mm
V
R
V
RMS
V DC V AC dV/dt in V/µs
50 20 2.5 1.5
100 35 13 9 6
160 60 20 12 8
250 90 23 16 10
630 200 40 26 18
k
0
values
Length of capacitor 18.5 mm 21 mm 34 mm
V
R
V
RMS
V DC V AC k
0
in V
2
/µs
50 20 250 150
100 35 2 600 1 800 1 200
160 60 6 400 3 840 2 560
250 90 11 500 8 000 5 000
630 200 50 400 32 800 22 700
B32537
High reliability (wound)
Page 8 of 20Please read Cautions and warnings and
Important notes at the end of this document.

B32537B8335K

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Film Capacitors 3.3uF 630volts 10% Axial
Lifecycle:
New from this manufacturer.
Delivery: