1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Specifications and characteristics in brief
Rated voltage V
R
Surge voltage V
S
25 ... 100 V DC
1.15 V
R
Rated capacitance C
R
Capacitance tolerance
1500 ... 330000 µF
±20% M
Leakage current I
leak
(20 °C, 5 min)
Self-inductance ESL Approx. 20 nH
Capacitors with low-inductance design:
d ≥ 64.3 mm: approx. 13 nH
Useful life
1)
Requirements:
105 °C; V
R
; I
AC,R
> 3000 h ∆C/C ≤ ±45% of initial value
85 °C; V
R
; I
AC,max
> 6000 h ESR ≤ 3 times initial specified limit
40 °C; V
R
; 2.2 I
AC,R
> 250000 h I
leak
≤ initial specified limit
Voltage endurance test
Post test requirements:
105 °C; V
R
2000 h ∆C/C ≤ ±15% of initial value
ESR ≤ 1.3 times initial specified limit
I
leak
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
IEC climatic category To IEC 60068-1:
40/105/56 (40 °C/+105 °C/56 days damp heat test)
Detail specification
Sectional specification
Similar to CECC 30301-810
IEC 60384-4
Ripple current capability
Due to the ripple current capability of the contact elements, the following current upper limits must
not be exceeded:
Capacitor diameter ≤ 51.6 mm 64.3 mm 76.9 mm
I
AC,max
34 A 45 A 57 A
B41560, B41580
Extremely compact 105 °C
Page 3 of 17Please read Cautions and warnings and
Important notes at the end of this document.