MB3773
13
APPLICATION CIRCUIT
EXAMPLE 1: Monitoring 5V Supply Voltage and Watch-dog Timer
VCC (5V)
MB3773
RESET
RESET
CK
GND
Logic circuit
Notes : Supply voltage is monitored using VS.
Detection voltage are V
SH and VSL.
C
T
1
2
3
4
8
7
6
5
EXAMPLE 2: 5V Supply Voltage Monitoring (external fine-tuning type)
VCC (5V)
1
2
3
4
8
7
6
5
MB3773
RESET
RESET
CK
GND
Logic circuit
Notes : Vs detection voltage can be adjusted externally.
Based on selecting R
1 and R2 values that are sufficiently lower than the resistance of the IC’s
internal voltage divider, the detection voltage can be set according to the resistance ratio of
R
1 and R2 (Refer to the table below.)
R1
R2
CT
R1 (k)R2 (k) Detection voltage: VSL (V) Detection voltage: VSH (V)
10 3.9 4.4 4.5
9.1 3.9 4.1 4.2
MB3773
14
EXAMPLE 3: With Forced Reset (with reset hold)
V
CC
1
2
3
4
8
7
6
5
MB3773
RESET
RESET
CK
GND
Logic circuit
Note : Grounding pin 7 at the time of SW ON sets RESET (pin 8) to Low and RESET (pin 2) to High.
SW
VCC
1
2
3
4
8
7
6
5
MB3773
RESET
RESET
CK
GND
Logic circuit
Note : Feeding the signal to terminal RESIN and turning on Tr sets the RESET terminal to Low and
the RESET terminal to High.
10 k
Tr
RESIN
10 k
Cr
C
T
(a)
(b)
MB3773
15
EXAMPLE 4: Monitoring Two Supply Voltages (with hysteresis, reset output and NMI)
V
CC1 (5 V)
1
2
3
4
8
7
6
5
MB3773
RESET
RESET
CK
GND
Comp. 2
Example : Comp. 1, Comp. 2
: MB4204, MB47393
NMI
or port
R6
+
_
+
_
VCC2(12 V)
180 k
R
4
30 k
R
3
5.1 k
R
2
1.2 k
R
1
4.7 k
R
5
Comp. 1
Notes : The 5 V supply voltage is monitored by the MB3773.
The 12 V supply voltage is monitored by the external circuit. Its output is connected to the NMI
terminal and, when voltage drops, Comp. 2 interrupts the logic circuit.
Use V
CC1 ( = 5 V) to power the comparators (Comp. 1 and Comp. 2) in the external circuit shown
above.
The detection voltage of the V
CC2 ( = 12 V) supply voltage is approximately 9.2 V/9.4 V and has
a hysteresis width of approximately 0.2 V.
V
CC2 detection voltage and hysteresis width can be found using the following formulas:
Detection voltage
Hysteresis width V
HYS = V2H V2L
R3 + (R4 // R5)
R
4 // R5
× VREF
V2L =
R3 + R5
R5
× VREF
(Approximately 9.4 V in the above illustration)
(Approximately 9.2 V in the above illustration)
C
T
Logic circuit
V2H =
10 k

MB3773PF-G-BND-JN-ERE1

Mfr. #:
Manufacturer:
Fujitsu
Description:
IC PWR SUPPLY MON W/WD 8SOP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union