1
Solid-state Timer H3Y
Miniature Timer Compatible with the MY
Relay
Large transparent time-setting knob facilitates time
setting. Flat-blade and Phillips screwdrivers can
also be used for time setting.
Approved by UL and CSA.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
High repeat accuracy.
RC
Ordering Information
Operation/resetting Time-limit contact Time ranges Supply voltage
Model
system
Surface /DIN-track
mounting (with socket)
Time-limit operation/ DPDT 0.1 s to 60 s
110 VAC
H3Y-2
self-resetting
220 VAC
24 VDC
4PDT
110 VAC
H3Y-4
220 VAC
24 VDC
Note: 1. Specify the model number, supply voltage, and rated time when ordering.
Ex. H3Y-2 110 VAC 1 s
Rated time
Supply voltage
2. Track mounted socket can be used as a front connecting socket.
Accessories
Track mounted socket
Back connecting socket
(see note 2)
Solder terminal Wire-wrap terminal PC terminal
PYF08A PY08 PY08QN(2) PY08-02
PYF14A PY14 PY14QN(2) PY14-02
Specifications
Time Ranges
Rated time 1 s 5 s 10 s 30 s 60 s
Time setting range 0.1 to 1 s 0.2 to 5 s 0.5 to 10 s 1.0 to 30 s 2.0 to 60 s
H3Y
H3Y
2
Ratings
Item H3Y-2/H3Y-4
Rated supply voltage 110, 220 VAC (50/60 Hz), 24 VDC (see note)
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 100 VAC: Relay ON: 1.5 VA (1.3 W)
Relay OFF: 0.8 VA (0.5 W)
200 VAC: Relay ON: 1.8 VA (1.5 W)
Relay OFF: 1.2 VA (0.9 W)
24 VDC: Relay ON: 0.9 W
Relay OFF: 0.07 W
Control outputs H3Y-2: 5 A at 250 VAC, resistive load (cosφ = 1)
H3Y-4: 3 A at 250 VAC, resistive load (cosφ = 1)
Note: With DC ratings, single-phase full-wave rectified power sources may be used.
Characteristics
Accuracy of operating time ±2% max.
Setting error ±10% (max. time division at rated voltage and room temperature)
Reset time 0.1 s max.
Influence of voltage ±2% max.
Influence of temperature ±5% max.
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed
non-current-carrying metal parts) (see note)
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) (see note)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) (see note)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz with 1.0-mm double amplitude
Malfunction: 10 to 55 Hz with 1.0-mm double amplitude
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 100 m/s
2
(approx. 10G)
Ambient temperature Operating: –10°C to 50°C (with no icing)
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h)
EMC Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
Immunity ESD: IEC801-2: 4 kV contact discharge (level 2)
4 kV air discharge (level 2)
Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: IEC801-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Approved standards UL (File No. E41515), CSA (File No. LR22310)
Conforms to EN50081-2, EN50082-2
Weight Approx. 50 g
Note: Terminal screw sections are excluded.
H3Y
H3Y
3
Engineering Data
H3Y-2
Switching operations (x 10 )
3
Load current (A)
H3Y-2
H3Y-4
Switching operations (x 10 )
3
Load current (A)
Switching operations (x 10 )
3
Load current (A)
H3Y-4
Switching operations (x 10 )
3
Load current (A)
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
Reference: A maximum current of 0.6 A can
be switched at 125 VDC (cosφ =
1). Maximum current of 0.2 A can
be switched if L/R is 7 ms. In both
cases, a life of 100,000 opera-
tions can be expected.
The minimum applicable load is 1
mA at 5 VDC (P reference value).
Reference: A maximum current of 0.5 A can
be switched at 125 VDC (cosφ =
1). Maximum current of 0.2 A can
be switched if L/R is 7 ms. In both
cases, a life of 100,000 opera-
tions can be expected.
The minimum applicable load is 1
mA at 1 VDC (P reference value).
Operation
Timing Chart
H3Y-2 H3Y-4
Time limit contact
NC (9-1, 12-4)
Time limit contact NC
(9-1, 10-2, 11-3, 12-4)

PY08

Mfr. #:
Manufacturer:
Description:
Relay Sockets & Hardware DPDT SOLDER SOCKET
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet