MPZ2012S300ATD25

7
FH48 Series0.5 mm Pitch, 6.18 mm Height, Vertical Mount, Shielded FFC High Speed Connectors
B
Connector handling and precautions
Handling and precautions
Care must be taken to the handling of this connector. Check the followings before using the product. The fi gures and values
described in the precautions may differ from the standard values of the product.
[Precautions for board implementation]
Board warp
Avoid board warp if possible.
The flatness of the connector is 0.1mm or smaller, and a large warp could cause solder failure.
Load on connector
When the emboss is extracted from the reel or when the connector is vacuum picked up from the emboss, avoid an
excessive force (over 1 N) to the un-mounted connector. Otherwise the connector could be damaged.
Also, do not insert FFC or handle the connector before inserting the connector.
[Precautions for board handling after implementation]
Load on board
-When a board is divided to make multiple boards
-When a board is fixed with screws.
In the assembling process such as the above, no load should be applied to
the board. Otherwise the connector could be damaged.
Board warp
When the board width is 100mm, the board warp should be 1mm or smaller
for the use. (Right figure)
The board warp could cause a load on the connector and damage it.
[Precautions for FFC insertion and mating]
Opening and closing of actuator
The connector, when delivered, is ready for FFC insertion. When FFC is inserted and the actuator is rotated by 90°,
the connector is in a FFC mating locked state. Do not rotate the actuator before inserting FFC.
Contact direction
Insert the connector with the FFC’s exposed conductor side on the housing and with the FFC stiffening plate on the
actuator.
FFC insertion
Securely insert FFC vertically to the connector.
6XijVidg
=djh^c\
.%
8dccZXidg^cYZa^kZgnhiViZ
;;8XVcWZ^chZgiZY#
;;8bVi^c\adX`ZY
6XijVidg
6XijVidg
;;8^chZgi^dchiVgih
:medhZY[VXZd[;;8XdcYjXidg
;;8hi^[[Zc^c\eaViZ
8dccZXidg
8dccZXidg
7dVgY
7dVgY
&B6M
&%%
&B6M
&%%
Apr.1.2017 Copyright 2017 HIROSE ELECTRIC CO., LTD. All Rights Reserved.
8
FH48 Series0.5 mm Pitch, 6.18 mm Height, Vertical Mount, Shielded FFC High Speed Connectors
Handling and precautions
Actuator handling
(1) The actuator can rotate about the rotation axis. Handle it as it rotates.
(2) The actuator does not rotate by more than 90°. Do not apply an excessive force to rotate it more. Otherwise the
terminal is deformed or the actuator is damaged.
(3) Do not pull or hook the actuator. Otherwise damage could be caused. (Only the rotation motion described above is
allowed.)
Check of lock
(1) When locking the actuator, make sure that it is parallel to the board face.
(2) After mating and locking FFC, make sure that the FFC positioning tab does not come on the FFC positioning
guide. If the FFC positioning tab runs over the FFC positioning guide, contact failure could be caused.
[Precautions for FFC handling after mating FFC]
Load on FFC
When handling FFC, do not apply a load directly to it.
If FFC is bent near the connector when it is used, contact
failure ordisconnection or damage of FFC could be
caused.
In particular, do not bend FFC sharply at the insertion
point to the actuator direction.
[Precautions for pulling FFC]
FFC needs to be pulled out with the actuator locked.
To circumvent the FFC positioning guide, pull it out at an angle
of about 7° from the perpendicular direction to the board.
[Other precautions]
Precautions for manual soldering
For manual soldering for repair or other purposes, see the followings.
(1) Do not make reflow or manual soldering with FFC inserted in the connector.
(2) Do not apply excessive heat. Prevent a soldering iron from contacting a part other than the lead wire of the
connector. Otherwise the connector may deform or melt.
(3) Do not supply an excessive amount of solder (flux).
If too much solder (flux) is applied on the terminal, a part of the solder or flux would adhere to the contact or
actuator’s rotation axis and cause contact failure or rotation failure of the actuator.
.%
GdiVi^dcVm^h
;;8edh^i^dc^c\\j^YZ
;;8edh^i^dc^c\iVW
Load: 0.05x n N MAX
(n: No. of pos.)
;;8edh^i^dc^c\\j^YZ
,
;;8edh^i^dc^c\iVW
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 11/2013. Contents are subject to change without notice for the purpose of improvements.
6-3,Nakagawa Chuoh-2-Chome,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
TEL:
+
81-45-620-3526 Fax:
+
81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
®
Apr.1.2017 Copyright 2017 HIROSE ELECTRIC CO., LTD. All Rights Reserved.
Powered by TCPDF (www.tcpdf.org)

MPZ2012S300ATD25

Mfr. #:
Manufacturer:
TDK
Description:
Ferrite Beads 0805 30ohms 6000mA Power Line AEC-Q200
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet