December 1990 5
Philips Semiconductors Product specification
Quad bilateral switches 74HC/HCT4016
RATINGS
Limiting values in accordance with the Absolute Maximum System (IEC 134)
Voltages are referenced to GND (ground = 0 V)
RECOMMENDED OPERATING CONDITIONS
SYMBOL PARAMETER MIN. MAX. UNIT CONDITIONS
V
CC
DC supply voltage −0.5 +11.0 V
±I
IK
DC digital input diode current 20 mA for V
I
<−0.5 V or V
I
> V
CC
+ 0.5 V
±I
SK
DC switch diode current 20 mA for V
S
<−0.5 V or V
S
> V
CC
+ 0.5 V
±I
S
DC switch current 25 mA for −0.5 V < V
S
< V
CC
+ 0.5 V
±I
CC
; ±I
GND
DC V
CC
or GND current 50 mA
T
stg
storage temperature range −65 +150 °C
P
tot
power dissipation per package for temperature range: −40 to +125 °C
74HC/HCT
plastic DIL 750 mW above +70 °C: derate linearly with 12 mW/K
plastic mini-pack (SO) 500 mW above +70 °C: derate linearly with 8 mW/K
P
S
power dissipation per switch 100 mW
SYMBOL PARAMETER
74HC 74HCT
UNIT CONDITIONS
min. typ. max. min. typ. max.
V
CC
DC supply voltage 2.0 5.0 10.0 4.5 5.0 5.5 V
V
I
DC input voltage range GND V
CC
GND V
CC
V
V
S
DC switch voltage range GND V
CC
GND V
CC
V
T
amb
operating ambient temperature range −40 +85 −40 +85 °C
see DC and AC
CHARACTERIS-
TICS
T
amb
operating ambient temperature range −40 +125 −40 +125 °C
1000 V
CC
= 2.0 V
t
r
,t
f
input rise and fall times 6.0 500
400
250
6.0 500 ns V
CC
= 4.5 V
V
CC
= 6.0 V
V
CC
= 10.0 V