CRT1-VID08S-1

52 Digital I/O Slave Units with e-CON Connector (Vertical type) CRT1-VID08S(-1)/VOD08S(-1)
Digital I/O Slave Units with e-CON Connector (Vertical type)
CRT1-VID08S(-1)/VOD08S(-1)
A vertical slave unit of little wiring and size
Industrial standard e-CON connectors allow direct connection of the unit
to sensing devices without use of terminal blocks. This minimizes
requirement in installation space and wiring work.
• Industrial standard e-CON connectors require less wiring work.
• Connector interface of input and output sections can downsize the unit.
• Various data such as network status at start-up, equipment operation and
deterioration can be provided.
• DIN tracks and metal fixtures allow flexible installation.
Ordering Information
* These Units are also available with a DCN-TB4 Terminal Conversion Adapter included in the package. Add "(-B)" to the end of the model number to receive the
Adapter as well.
Performance Specifications
For Basic Performance Specifications of Slave Units, refer to page 32.
Name Specifications Model
e-CON Connectors *
Inputs 8 inputs
NPN
Without Short-circuit and Disconnected Line
Detection
CRT1-VID08S
PNP CRT1-VID08S-1
Outputs 8 outputs
NPN CRT1-VOD08S
PNP
CRT1-VOD08S-1
Mounting Bracket
Unit with e-CON Connectors
CRT1-V@D08S(-1)
CRT1-ATT02
Slave External I/O Connections in the appendix for applicable connectors.
Digital I/O Slave Units with e-CON Connector (Vertical type) CRT1-VID08S(-1)/VOD08S(-1) 53
Input Section Specifications Output Section Specifications
Dimensions (Unit: mm)
Item Specification
Model CRT1-VID08S CRT1-VID08S-1
I/O capacity 8 inputs
Internal I/O common NPN PNP
ON voltage
10.5 VDC min.
(between each
input terminal and
the V terminal)
10.5 VDC min.
(between each
input terminal and
the G terminal)
OFF voltage
5 VDC max.
(between each
input terminal and
the V terminal)
5 VDC max.
(between each
input terminal and
the G terminal)
OFF current 1.0 mA max.
Input current
At 24 VDC: 6.0 mA max./input
At 11 VDC: 3.0 mA min./input
ON delay 1.5 ms max.
OFF delay 1.5 ms max.
Number of circuits per common 8 inputs/common
Isolation method Photocoupler
Input indicator LED (yellow)
Installation DIN Track or Mounting Bracket
Power supply type Network power supply
Power short-circuit protection Operates at 50 mA/point min.
Current supplied to input devices
50 mA/input
Communications power supply
current consumption
35 mA max. for 24-VDC power supply
voltage
50 mA max. for 14-VDC power supply
voltage
Weight 80 g max.
Item Specification
Model CRT1-VOD08S CRT1-VOD08S-1
I/O capacity 8 outputs
Internal I/O common NPN PNP
Rated output current 0.3 A/output, 2 A/common
Residual voltage
1.2 V max. (0.3 A
DC, between each
output terminal and
the G terminal)
1.2 V max. (0.3 A
DC, between each
output terminal and
the V terminal)
Leakage current 0.1 mA max.
ON delay 0.5 ms max.
OFF delay 1.5 ms max.
Number of circuits per common 8 outputs/common
Isolation method Photocoupler
Output indicators LED (yellow)
Installation DIN Track or Mounting Bracket
Power supply type Multi-power supply
Current supplied to output
devices
100 mA/output
Communications power supply
current consumption
40 mA max. for 24-VDC power supply
voltage
60 mA max. for 14-VDC power supply
voltage
I/O power supply current
consumption
15 mA max. for 24-VDC power supply
voltage
Output handling for
communications errors
Select either hold or clear from CX-
Integrator.
Weight 80 g max.
The numbers inside the parentheses
are reference dimensions.
66.2
60
(101.7)
90
5.3
23
(102)
(90)
96.7
6.4
85.7
92.8
CRT1-VID08S (-1)
CRT1-VOD08S (-1) When a DCN4-TB4 Open Type Connectors Is Mounted
Mounting Holes
13 26.7
16±
0.2
2-3.2 dia. or M3
35
Mounting Bracket
CRT1-ATT02
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2011.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.

CRT1-VID08S-1

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
I/O Connectors 8 In PNP Vert Econ
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet