BXA10-48D12-S

DC/DC CONVERTERS 8-10W Wide Input DC/DC Converters 1
2 YEAR WARRANTY
BXA10 Series
Single and dual output
1 x 2 x 0.395 inch package with stand-offs
13.3 Watts/in
3
power density
CISPR22 and EN55022 conducted emission level A
UL, CSA and VDE approvals (48V input only)
Continuous short circuit protection
Optional remote ON/OFF
The BXA10 series of DC/DC converters, comprising 7 different models, is designed for
a wide range of applications including communications, industrial systems and mobile
battery powered systems. Packing up to 10 Watts of power into a 2 x 1 x 0.395 inch
package, with efficiencies as high as 85%, the BXA10 has wide input ranges of 9-18VDC
and 18-75VDC, and is available in single and dual output versions. Isolation of 1500VDC,
approval to EN60950 2nd edition, coupled with reduced conducted noise for simplified
compliance to FCC Part 15 level A and EN55022 level A, make the BXA10 ideal for
telecommunications and distributed power applications. Other features include
overvoltage protection, continuous short circuit protection with automatic recovery and
remote on/off, all of which minimize the need for external circuitry and make the BXA10 a
recommended component in distributed power systems.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC, (See Note 8) Level A
ESD air EN61000-4-2, level 2 Perf. criteria 1
ESD contact EN61000-4-2, level 3 Perf. criteria 1
Surge EN61000-4-5, level 2 Perf. criteria 1
Fast transients EN61000-4-4, level 2 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output 1500VDC
Input or output to case 1000VDC
Switching frequency Fixed 400kHz
Approvals and Safety VDE0805, EN60950, IEC950
standards UL1950, CSA C22.2 No. 950
Case material Black coated, six-sided metal case
Material flammability UL94V-0
Weight 20g (0.71oz)
MTBF MIL-HDBK-217F 519,000 hours
Bellcore >2 million hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -25°C to +71°C
(See derating curve)
Non-operating amb. -55°C to +125°C
Case +110°C max.
Derating See derating curve
Cooling Free air convection cooled
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non operating 40,000 feet max.
Vibration 5Hz to 500Hz 2.5G rms (approx.)
SPECIFICATIONS
File Name: BXA10.PDF Rev: 02 Oct 2002
OUTPUT SPECIFICATIONS
Line regulation LL to HL, single output ±0.2%
LL to HL, dual output ±0.2%
Load regulation 10% to 100% FL (See Note 4) ±0.5%
Minimum load 48V models 10% full load
12V models No minimum load
Overshoot At start-up 10% max.
Ripple and noise 5Hz to 20MHz 100mV pk-pk, max.
(See Note 2) 20mV rms
Transient response 25% load step ±2.0% max. dev.,
250µs recovery
to within ±1.0%
Temperature coefficient ±0.02%/°C max.
Overvoltage protection Clamp type See table
Short circuit protection Hiccup Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range 12VDC (See Note 6) 9 to 18VDC
48VDC 18 to 75VDC
Input filter Pi type
Start up surge current Resistive load 1.5A max.
Remote ON/OFF Open collector compatible
ON (See Note 3) High impedance >400k
OFF Low impedance <1.0k
OFF idle current <1.5mA
Start-up time 1.6s, max.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1 At nominal input and output voltage and maximum load.
2 Output ripple can be reduced to <50mV with the addition of a 33µF, 25V,
AVX-TPS (or equivalent) tantalum capacitor. Consult factory for further
information.
3 For units with optional remote ON/OFF, please add the suffix ‘-S’ to the
model number: e.g. BXA10-48S05-S. Maximum open pin voltage 14VDC.
4 Assumes balanced loads on dual output models.
5 High impedance source/long input power cable may necessitate the
introduction of an input filter.
6 Typical 9-18VDC model start-up voltage is 9V. Maximum start-up voltage
is 9.5V (>0°C) or 9.7V (<0°C).
7 It is recommended that an IEC127, 250V, fast blow fuse is used rated at
4A for nominal 12V models and 2A for 48V models.
8 To achieve compliance to EN55022-A and FCC part 15 Class A, external
capacitors of the following values are needed:
Model C1* C2 C3
BXA10-12xxx 10µF film, 25V 0.22µF film 0.22µF film
BXA10-48xxx 10µF film, 100V 0.22µF film 0.22µF film
(C2, C3 voltage rating application dependent)
* Siemens P.N. B32512-J1106-J or equivalent.
BXA10 Series
Single and dual output
DC/DC CONVERTERS 8-10W Wide Input DC/DC Converters 2
www.artesyn.com
File Name: BXA10.PDF Rev: 02 Oct 2002
* Optional remote ON/OFF pin. Add Suffix ‘-S’ to the model number, Note 3.
INPUT OUTPUT OUTPUT INPUT TYPICAL
OVP
REGULATION (Typ.) MODEL
VOLTAGE VOLTAGE CURRENT CURRENT
(1)
EFFICIENCY LINE LOAD NUMBER
(3)
9-18VDC 5.0V 2.0A 1.1A 81% 6.2VDC ±0.2% ±0.5% BXA10-12S05
9-18VDC 15.0V 0.67A 1.05A 85% 18VDC ±0.2% ±0.5% BXA10-12S15
9-18VDC ±5.0V ±1.0A 1.05A 81% 12VDC ±0.2% ±0.5% BXA10-12D05
18-75VDC 5.0V 2.0A 0.26A 82% 6.8VDC ±0.2% ±0.5% BXA10-48S05
18-75VDC ±5.0V ±1.0A 0.26A 82% 12VDC ±0.2% ±0.5% BXA10-48D05
18-75VDC ±12.0V ±0.416A 0.25A 84% 30VDC ±0.2% ±0.5% BXA10-48D12
18-75VDC ±15.0V ±0.333A 0.25A 84% 36VDC ±0.2% 0.5% BXA10-48D15
PIN CONNECTIONS
PIN NUMBER SINGLE OUTPUT DUAL OUTPUT
1+Vin + Vin
2 – Vin – Vin
3 + Vout + Vout
4 No Pin Common
5 – Vout – Vout
6* Remote ON/OFF Remote ON/OFF
100%
Ambient Temperature (˚C)
Output Power (%)
0%
0ºC 20ºC 40ºC 60ºC 80ºC 100ºC 120º C
-25ºC
110ºC
DERATING CURVE
Output Power (Watts)
71ºC
BOTTOM VIEW
2.0
(50.8)
0.8
(20.4)
0.6
(15.2)
0.4
(10.2)
0.2
(5.1)
0.3
(7.6)
1.00 (25.4)
0.040 Dia. (1.0)
0.020
(0.5)
0.395 (10.03)
max.
0.4
(10.2)
0.1
(2.5)
345
621
0.135 ± 0.010
(3.4 ± 0.2)
0.4
(10.2)
ALL DIMENSIONS IN INCHES (mm)
BOTTOM VIEW
+ Input
Input Return
C1
C2 C3
Ground Plane
BXA10
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-1094
Licence No. 6298 and 6299
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Data Sheet © Artesyn Technologies
®
2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
BXA10 Series
Single and dual output
DC/DC CONVERTERS 8-10W Wide Input DC/DC Converters 3
www.artesyn.com
File Name: BXA10.PDF Rev: 02 Oct 2002
Mechanical Notes
A Recommended PCB hole diameter is 0.052 inches (1.32mm).
B All pins are in true position within 0.010 inches (0.25mm).
C Tolerance (inches): .XX = ±0.02
XXX = ±0.005

BXA10-48D12-S

Mfr. #:
Manufacturer:
Description:
Module DC-DC 2-OUT 12V/-12V 0.416A/-0.416A 10W 6-Pin
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union