GP25A series
25W AC-DC Triple Output IndustrialAdaptor
SPECIFICATION
GP25A13A-R1B GP25A13D-R1B GP25A14E-R1B
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED SET CURRENT
CURRENT RANGE
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
NOTE
OVERLOAD
OVER VOLTAGE
PROTECTION
5V
GP25A13A GP25A13D GP25A14E
12V 5V 12V 5V 15V
2.5A 1.2A 2.5A 1A 2.5A 0.8A
0.5 ~ 2.5A 0.2 ~ 1.2A 0.5 ~ 2.5A 0.2 ~ 1A 0.5 ~ 2.5A 0.1 ~ 0.8A
RATED POWER
800ms, 50ms, 20ms / 230VAC 1200ms, 50ms, 16ms / 115VAC at full load
90 ~ 264VAC 135~ 370VDC
47 ~ 63Hz
0.8A / 100VAC 0.4A / 230VAC
80% 80% 80.5%
Cold start 30A / 115VAC 60A / 230VAC
0.75mA / 240VAC
IEC60950-1, UL60950-1, CSA22.2, EN60950-1, approved
EAC TP TC 004
WITHSTAND VOLTAGE
I/P-O/P:4242VDC , I/P-FG:2121VDC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-20 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03% / (-20 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
CONNECTOR
-5V
0.3A
0.1 ~ 0.3A
-12V
0.3A
0.1 ~0.3A
-15V
0.3A
0.1 ~ 0.3A
RIPPLE & NOISE (max.)
Note.3 50mVp-p
28.5W 28W 29W
100mVp-p 60mVp-p 120mVp-p 100mVp-p 150mVp-p50mVp-p 50mVp-p 50mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% -5.0 ~ +10% ±5.0% -5.0 ~ +5.0% ±5.0% -5.0 ~ +15%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±5.0% ±5.0% ±5.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0%
110 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode(5V only), output short
MTBF
DIMENSION
PACKING
ISOLATION RESISTANCE
620K hrs min. MIL-HDBK-217F (25 )℃
107.5*67*36mm (L*W*H)
0.3kg; 54pcs / 20kg / CARTON
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.When measured between the light load (20% of rated load) and full load, the load regulation is within 5% whereas the cross regulation is within 15%.±±
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
3 years : 100% load 40 , 8hours day℃/
PLUG
CABLE
See page 4
See page 4
LIFE
SAFETY &
EMC
(Note. 8)
EMC IMMUNITY
EMC EMISSION
Parameter
Standard
EN55032(CISPR32),FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
EN55032(CISPR32),FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-11
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 3, 1KV/L-N, 2KV/L,N-PE
Level 2, 3V
Level 2, 1KV
RF field
susceptibility
Voltage dips , interruption
File Name:GP25A-SPEC 2018-01-15