DG441/442
Vishay Siliconix
www.vishay.com
4
Document Number: 70053
S-20147—Rev. H, 11-Mar-02
SPECIFICATIONS
a
FOR SINGLE SUPPLY
Test Conditions
Otherwise Unless Specified
A Suffix
–55 to 125_C
D Suffix
–40 to 85_C
Parameter Symbol
V+ = 12 V, V– = 0 V, V
IN
= 2.4 V,
0.8 V
f
Temp
b
Typ
c
Min
d
Max
d
Min
d
Max
d
Unit
Analog Switch
Analog Signal Range
e
V
ANALOG
Full 0 12 0 12 V
Drain-Source
On-Resistance
r
DS(on)
I
S
= –10 mA, V
D
= 3 V, 8 V
V+ = 10.8 V
Room
Full
100 160
200
160
200
Dynamic Characteristics
Turn-On Time t
ON
R
L
= 1 k , C
L
= 35 pF
Room 300 450 450
Turn-Off Time t
OFF
R
L
= 1 k
, C
L
= 35 pF
V
S
= 8 V, See Figure 2
Room 60 200 200
ns
Charge Injection Q
C
L
= 1 nF V
gen
= 6 V, R
gen
= 0
Room 2 pC
Power Supplies
Positive Supply Current I+ Full 15 100 100
Negative Supply Current I–
V+ = 13.2 V, V– = 0 V
V
IN
= 0 or 5 V
Room
Full
–0.0001 –1
–100
–1
–100
A
Ground Current I
GND
IN
Full –15 –100 –100
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.