P981-0107-350BAS15

SENSOR SOLUTIONS ///P900
Page 1
08/2017
P900
SPECIFICATIONS
Field proven rugged construction
High overpressure capability
High reliability for demanding environments
Application specific customization
Excellent media compatibility
Shock and vibration resistant
P900 Series Strain Gauge Pressure Transducers are
premium grade sensors that provide highly precise
measurement of absolute, vented gauge, or sealed
gauge pressures over wide temperature ranges.
Standard versions of this transducer use a 17-4 PH
stainless steel diaphragm to sense pressure (Inconel
versions are available for operation in highly corrosive
environments). The deflection of the diaphragm is
transferred to a double cantilever beam by a force
transfer rod. Strain in the beam, and therefore, input
pressure is measured by four foil strain gauges.
An all-welded construction provides high reliability and
stability. Capable of sensing extremely small changes of
applied pressure, the transducers are relatively
insensitive to vibration, attitude, and shock.
The P900 Series Pressure Sensors are available in a
range of electrical inputs and outputs. Zero and span
potentiometers are available as a special option with the
P940, P950, P960, and P990 models. Non-standard
pressure ranges are available in all models of the P900
Series.
For parts requiring RoHS compliance, please contact
factory.
P900
SENSOR SOLUTIONS ///P900
09/2017
Page 2
FEATURES
High Overload capability
Operation in High Temperatures
Shock and Vibration Resistant
2-wire, 4-20 mA option; Intrinsic Safety
Approval to E Exia IIC T4 (T
amb
=60°C)
BASEEFA, CENELEC EN50-020
APPLICATIONS
PERFORMANCE SPECIFICATIONS
Series
P900
P940
P950
P960
P970
P980
P990
Model Number
P901/904
P941/4
P951/4
P961/4
P971/4
P981/4
P991/4
Input Voltage
10V
DC
(12 V max)
10V
DC
10V
DC
11-18V
DC
18-32V
DC
15-36V
DC
10-36V
DC
±15V
DC
Current
Consumption(mA)
13
20
20
20
20
-
20
Full Range Output
1%)
20mV
5V
DC
2.5V
DC
5V
DC
10V
DC
4-20mA
5V
DC
Impedance (ohm)
1000 ±5%
<10
<10
<10
<10
Load
Resist.
1300 max.
at 36V
DC
<10
Current (mA max)
-
5
5
5
5
-
5
Frequency Response
Approx. 2.5
kHz to 40 kHz
for .7 bar
1 kHz
1 kHz
1 kHz
1 kHz
100 Hz
1 kHz
Combined Thermal Zero & Sensitivity Shift
% F.R.O./°F
±0.008
±0.008
±0.008
±0.008
±0.008
±0.008
±0.008
% F.R.O./°C
±0.015
±0.015
±0.015
±0.015
±0.015
±0.015
±0.015
Residual Unbalance
% F.R.O.
±1
±1
±1
±1
±1
±1
±1
Weight oz (gm)
Connector Version
4.4 (125)
5.1 (145)
5.1 (145)
5.1 (145)
5.1 (145)
5.1 (145)
5.1 (145)
Cable Version
5.6 (160)
6.3 (180)
6.3 (180)
6.3 (180)
6.3 (180)
6.3 (180)
6.3 (180)
Hydraulic Pressure Monitoring
Torpedo Depth Sensing
Vehicle Brake System Monitoring
Military and Commercial Aircraft
P900
SENSOR SOLUTIONS ///P900
09/2017
Page 3
COMMON SPECIFICATIONS
Pressure Ranges
High
(psi)
0-75, 100, 150, 200, 250, 350, 500, 750, 1000, 1500, 2200, 3500, 5000, 7500,10,000
(bar)
0-8, 7, 10, 15, 25, 35, 50, 70, 100, 150, 200, 250, 350, 500, 700
Medium
psi
0-10, 15, 20, 25, 35
bar
0-0.7, 1.0, 1.5, 1.7, 2.5
DIN
bar
1, 1.6 ,2.5 ,4 ,6,10, 16, 25, 40, 60, 100, 160, 250, 400, 600
Pressure References
High pressure range
Vented gauge: 0-75 to 0-350psi
Absolute and sealed gauge: 0-75 to 0-10 ksi
Medium Pressure Range
Vented gauge and absolute: 0-10,15,20,25,35 psi (0-0.7,1.0,1.5,1.7,2.5 bar)
Pressure Limit
5X Full range pressure or 12,000 psi (830 bar), whichever is less. Will not cause a zero-
offset exceeding 0.04 FRO (recoverable within a few hours)
Burst Pressure
20 x full range pressure or 22,000 psi (1,520 bar), whichever is less
Pressure Media
Liquids or gases compatible with 17-4 PH and 17-7 PH stainless steel or Inconel 625
Shunt Calibration
80% ±5% full range pressure (not fitted in P980 Series)
Combined Non-linearity, Hysteresis and Non-
repeatability
High Range: <±0.10% F.R.O. (BSL)
Medium Range: <±0.20% F.R.O. (BSL)
Operable Temperature
65°F to 250°F (-54°C to 120°C)
P91X: -65°F to 300°F (-54°C to 150°C)
Compensated Temperature
32°F to 212°F (0°C to 100°C)
P91X: -65°F to 250°F (-54°C to 120°C) or -4°F to 176°F (20°C to +80°C)
Storage Temperature
-65°F to 300°F (-54°C to 150°C)
Humidity
95% Relative Humidity
Cable Version
Immersible to IP67 (fluid must not enter the ends of the cable)
Acceleration Response
Above 500 psi (35 bar) ±0.02% F.R.O./g; below 500 psi (35 bar) ±0.10% F.R.O./g
Vibration
Surpasses MIL STD810C Method 514-2 Curve L and EUROCAE ED 14A/RTCA 160A
Shock
1000g for 5msec will not damage the sensor
EMC
The P940, P950, P960 and P980 and P990 Series are CE marked, and when correctly
installed comply with the EMC Directive 89/336/EEC Generic Standards for Residential
Commercial, Light Industrial and Industrial environments.
Note: The P980 Series when used in Intrinsic Safety applications does not comply with the
Industrial environment directive.
Insulation Resistance
500 M at 50 V
DC
at 25
o
C
Total Thermal Error Band (P91X only)
-20
o
C to 80
o
C 0.4% FRO Typical, <±0.6% FRO Maximum
-54
o
C to 120
o
C 0.7% FRO Typical, <±1.0% FRO Maximum