cui.com
date 08/21/2012 │ page 2 of 5CUI Inc │ SERIES: EMSA 6W │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 0.3 A RMS
inrush current
9 V output at 115 V ac, cold start
9 V output at 230 V ac, cold start
all other outputs: 115 V ac, cold start
all other outputs: 230 V ac, cold start
15
30
30
60
A
A
A
A
no load power consumption 0.3 W
OUTPUT
parameter conditions/description min typ max units
line regulation ±3 %
load regulation ±5 %
PROTECTIONS
parameter conditions/description
over voltage protection protect through primary circuit IC
short circuit protection output shut down and auto restart
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute
3,000
4,242
Vac
Vdc
isolation resistance input to output at 500 V dc 100
MΩ
safety approvals UL 60950-1, EN 60950-1/IEC 60950-1, RCM, CCC, PSE
EMI/EMC FCC Part 15B, EN 55022B, CE
leakage current
9 V output
all other outputs
0.25
0.1
mA
mA
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 040°C
storage temperature -10 70 °C
operating humidity 20 80 %
storage humidity 10 90 %
For more information, please visit the product page | For information on related products, view Dc Power Jacks