LKT1AF-5V

–1–
ASCTB201E 201605-T
ORDERING INFORMATION
TYPES
Standard packing Carton: 100 pcs. Case: 500 pcs.
Note: 3 V, 6 V and 18 V DC types are also available. Please consult us for details.
RATING
1. Coil data
TV-8 rated.
1 Form A 5A power relays
LK-T RELAYS
Contact arrangement Nominal coil voltage Part No.
1 Form A
5V DC LKT1aF-5V
9V DC LKT1aF-9V
12V DC LKT1aF-12V
24V DC LKT1aF-24V
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
5V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
50.0mA 100Ω
250mW
6.5V DC
9V DC 27.8mA 324Ω 11.7V DC
12V DC 20.8mA 576Ω 15.6V DC
24V DC 10.4mA 2,304Ω 31.2V DC
Protective construction: Flux-resistant
type
RoHS compliant
FEATURES
1. High inrush current capability
1) Operating load capability:
inrush 118 A, steady 8 A
2) UL/C-UL TV-8 approved
2. Long insulation distance
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC60065)
2) Surge withstand voltage between
contact and coil: 10,000 V or more
3. Conforms to the various safety
standards
UL/C-UL, TÜV, and SEMKO approved
TYPICAL APPLICATIONS
• Audio visual equipment
• Flat TVs and audio equipment, etc.
• Office equipment
• Home appliances
LK-T relay
LKT 1a F
Protective construction
F: Flux-resistant type
Nominal coil voltage (DC)
5V, 9V, 12V, 24V
Contact arrangement
1a: 1 Form A
Notes: Certified by UL/C-UL, TÜV and SEMKO
LK-T
–2–
ASCTB201E 201605-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO2 type
Rating
Nominal switching capacity (resistive load) 5A 277V AC
Max. switching power (resistive load) 1,385VA
Max. switching voltage 277V AC
Max. switching current 8A (AC)
Min. switching capacity (reference value)*
1
100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 15 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 5 ms (excluding contact bounce time) (Without diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical (at 180 times/min.) Min. 10
6
Electrical (at 20 times/min.) Min. 10
5
(ON: 1.5s, OFF: 1.5s, at nominal switching capacity)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 12 g .42 oz
1. Max. switching power (AC resistive load) 2. Coil temperature rise
Sample: LKT1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 0 A, 8A
3. Ambient temperature characteristics and coil
applied voltage
100
10
1
5
0 10 100
Contact voltage, V
Contact current, A
800
0
5
10
15
20
25
30
100 120
20°C 8A
20°C 0A
70°C 8A
70°C 0A
Temperature rise, °C
Coil applied voltage, %V
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115°C 239°F)
120
300
200
100
0
100806040200
Ambient temperature, °C
Coil applied voltage, %V
Carrying current: 8A
Pick-up voltage (hot start)
Pick-up voltage (cold start)
4-(1). Electrical life test
(5 A 277 V AC, resistive load)
Sample: LKT1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
12V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
277V AC
0
0
2
4
6
8
10
12
510
Drop-out voltage
Pick-up voltage
Max.
Min.
x
Max.
Min.
x
No. of operations, ×10
4
Pick-up and drop-out voltage, V
0
0
5
10
15
20
25
30
35
40
45
50
105
Max.
Min.
x
No. of operations, ×10
4
Contact resistance, mΩ
LK-T
–3–
ASCTB201E 201605-T
DIMENSIONS (mm inch)
SAFETY STANDARDS
* CSA standard: Certified by C-UL
EN/IEC VDE Certified
INSULATION CHARACTERISTIC(IEC61810-1)
UL/C-UL (Recognized) VDE (Certified) TÜV (Certified)
File No. Contact rating Cycles File No. Contact rating Cycles File No. Contact rating Cycles
E43149 8A 277V AC General use 5 × 10
4
40014390 8A 250V AC (cos
φ
=1.0) 2 × 10
4
B 12 09 13461 333 8A 250V AC (cos
φ
=1.0) 2 × 10
4
5A 277V AC General use 10
5
—— ——
5A 30V DC Resistive 10
5
—— ——
SEMKO (Certified) TV Rating (UL/C-UL)
File No. Contact rating File No. Contact rating
1408509 3/100A 250V AC E43149 TV-8
5/40A 250V AC
Item Characteristic
Clearance/Creepage distance (IEC61810-1) Min. 5.5mm/5.5mm
Category of protection (IEC61810-1) RT II
Tracking resistance (IEC60112) PTI 175
Insulation material group III a
Over voltage category III
Rated voltage 250V
Pollution degree 2
Type of insulation (Between contact and coil) Reinforced insulation
Type of insulation (Between open contacts) Micro disconnection
4-(2). Electrical life test
(UL508 TV-8 rating test)
Sample: LKT1aF-12V, 6 pcs.
• Overload test
Load: 12 A 120 V AC (60 Hz),
Inductive load (cos
φ
= 0.75)
Operation frequency: 6 times/min
(ON : OFF = 1 s : 9 s)
No. of operations: 50 ope.
• Endurance test
Load: 8A 120 V AC (960 W lamp load),
(Inrush: 118 A)
Operation frequency: 1 times/min
(ON: OFF = 1 s: 59 s)
No. of operations: 25,000 ope.
Change of pick-up and drop-out voltage Change of contact resistance
025
0
2
4
6
8
10
12
Drop-out voltage
Pick-up voltage
Max.
Min.
x
No. of operations, ×10
3
Pick-up and drop-out voltage, V
Max.
Min.
x
0
0
5
10
15
20
25
30
35
40
45
50
25
Max.
Min.
x
No. of operations, ×10
3
Contact resistance, mΩ
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
4
0.5
1.65
Max. 25.0
Max. 11.0
0.3
0.5 dia.
20.0
16.5
0.4
Max. 24.0
7.5
1.0
.157
.020
.065
.984
.433
.012
.020 dia.
.787
.650
.016
.945
.295
.039
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
2-0.9 dia. 2-1.3 dia.
16.5
7.5
20.0
2-.035 dia. 2-.051 dia.
.650
.295
.787
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012

LKT1AF-5V

Mfr. #:
Manufacturer:
Panasonic
Description:
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet