https://www.phoenixcontact.com/us/produkte/1969386
11.10.2012Page2/5
Printed-circuit board connector-IPC 16/ 3-ST-10.16-1969386
Technical data
Technical data
Rated surge voltage (II/2) 6 kV
Rated voltage (III/2) 1000 V
Rated voltage (II/2) 1000 V
Connection in acc. with standard EN-VDE
Nominal current IN 76 A
Nominal voltage UN 1000 V
Nominal cross section 16 mm²
Maximum load current 76 A
Insulating material PA
Inflammability class according to UL 94 V0
Internal cylindrical gage A6
Stripping length 14 mm
Nominal voltage, UL/CUL Use Group B 600 V
Nominal current, UL/CUL Use Group B 55 A
Nominal voltage, UL/CUL Use Group C 600 V
Nominal current, UL/CUL Use Group C 55 A
Connection data
Conductor cross section solid min. 0.75 mm²
Conductor cross section solid max. 16 mm²
Conductor cross section stranded min. 0.75 mm²
Conductor cross section stranded max. 16 mm²
Conductor cross section stranded, with ferrule without plastic
sleeve min.
0.5 mm²
Conductor cross section stranded, with ferrule without plastic
sleeve max.
16 mm² Only in connection with CRIMPFOX 16 S
Conductor cross section stranded, with ferrule with plastic sleeve
min.
0.5 mm²
Conductor cross section stranded, with ferrule with plastic sleeve
max.
16 mm² Only in connection with CRIMPFOX 16 S
Conductor cross section AWG/kcmil min. 18
Conductor cross section AWG/kcmil max 6
2 conductors with same cross section, solid min. 0.75 mm²
2 conductors with same cross section, solid max. 6 mm²
2 conductors with same cross section, stranded min. 0.75 mm²
2 conductors with same cross section, stranded max. 6 mm²
2 conductors with same cross section, stranded, ferrules without
plastic sleeve, min.
0.5 mm²
2 conductors with same cross section, stranded, ferrules without
plastic sleeve, max.
4 mm²
2 conductors with same cross section, stranded, TWIN ferrules
with plastic sleeve, min.
0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules
with plastic sleeve, max.
6 mm²
Minimum AWG according to UL/CUL 20