■ Features
● 1 output
● UL60950 approved
●Applicable panel size*: 3 to 15 inches
●In the high-voltage generator(a terminal and a pattern),
an anti-dust measure by silicone application is taken.
(Notice) Applicable panel size becomes a standard.
Electrical Characteristics
Other Specifications
CXA-L0512-NJL
Non-dimming/Connector Type
CXA-L0512-NJL Specifications
(Please refer to each specification before use)
■ Applications
Item Unit Symbol
Specifi cation Condition
min typ max Vin(V) Ta(℃ ) RL(kΩ) Remark
Output Current mArms Iout
4.5 5.0 5.5 120.12 235 120
4.0 5.0 6.0 120.6 0 to +60 110 to 130
Input Current A Iin - 0.3 0.5 120.6 0 to +60 110 to 130
Frequency kHz Freq 33 40 47 120.6 0 to +60 110 to 130
Open Circuit Voltage
Vrms Vopen 1400 1500 - 120.6 0 to +60 ∞ Open load
Dimming Function
No
Operating Temperature
℃ 0 to +60
Storage Temperature
℃ -30 to +85
Operating Humidity Ratio
RH% 95Max
Safety Standard
UL60950
Weight g 11
Dimensions(WxDxH)
mm 80.5x20.5x8 (*1)
Fused Input Yes
Remote ON / OFF
No
Alarm Signal Function
No
Shutdown Function
No
Silicone Coating on
High Voltage Area
Yes
(*1) These dimensions are indicated the maximum.
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■
Conformity to RoHs Directive
001-01/20080228/etl_cxa_l0512_njl
All specifications are subject to change without notice.
1