HRPG-600-15

Universal AC input / Full range
Built-in active PFC function, PF>0.94
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in cooling fan ON-OFF control
DC OK signal Built-in
emote ON-OFF control Built-in r
Standby 5V@0.3A
Built-in remote sense function
No load power consumption<0.75W (Note.6)
Current sharing up to 2400W (3+1) (24V,36V,48V)
5 years warranty
SPECIFICATION
HRPG-600-3.3 HRPG-600-5 HRPG-600-7.5 HRPG-600-12 HRPG-600-15 HRPG-600-24 HRPG-600-36 HRPG-600-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
FUNCTION
EMC
(Note 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
DC OK SIGNAL
REMOTE CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
AC CURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
120A
120A 80A 53A 43A 27A 17.5A 13A
0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A
396W 600W 600W 636W 645W 648W 630W 624W
100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.94/230VAC PF>0.99/115VAC at full load
78.5% 82%
6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
86% 88% 88% 88% 89% 89%
7.6A/115VAC 3.6A/230VAC
35A/115VAC 70A/230VAC
<1.2mA / 240VAC
105 ~ 135% rated output power
3.96 ~ 4.62V
Protection type :
Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL60950-1, TUV EN60950-1 EAC TP TC 004 approved
,
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-40 ~ +70 (Refer to "Derating Curve")
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
147.7K hrs min. MIL-HDBK-217F (25 )
218*105*63.5mm (L*W*H)
File Name:HRPG-600-SPEC 2018-01-15
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
HRPG-600 series
600W Single Output with PFC Function
1.58Kg;8pcs/13.6Kg/1.34CUFT
5V STANDBY
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)±
FAN CONTROL (Typ.)
Load 35 15% or RTH2 50 Fan on±≧
EMC IMMUNITY
EMC EMISSION
The 5V standby must be connected
with a minimum load of 0.03A.
Mechanical SpecificationMechanical Specification
Case No. 977A Unit:mm
AC Input Terminal Pin No.
Assignment
DC Output Terminal Pin No.
Assignment
Pin No. Pin No.
1 1~3
3
2 4~6
Assignment Assignment
AC/N +V
AC/L -V
FG
Derating Curve Output Derating VS Input Voltage
INPUT VOLTAGE (V) 60Hz
85 100 125 135 155 264
100
90
80
70
60
50
40
LOAD(%)
AMBIENT TEMPERATURE ( )
LOAD (%)
-40 10 20 30 40 50 60 70
20
50
80
100
125
(HORIZONTAL)
PWM fosc : 70KHz
CN100
LED
(VoADJ.)SVR1
Block Diagram
Pin No. Pin No.
7
6,8
5
3
2
1
9
4
10
Assignment
-S
+S
DC-OK
GND
CS
Assignment
RC-
RC+
AUX
AUXG
Mating Housing Terminal
or equivalent or equivalent
Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent
HRS DF11-10DS
HRS DF11-**SC
O.L.P.
O.T.P.
EMI
INRUSH
ACTIVE
FILTER
CURRENT
LIMITING
RECTIFIERS
&
PFC
I/P
FG
PWM
PFC
CIRCUIT
SHARING
DETECTION
CURRENT
POWER
AUX
SWITCHING
POWER
FILTER
FILTER
&
&
RECTIFIERS
RECTIFIERS
+V
+S
AUX
CONTROL
CONTROL
O.V.P.
O.T.P.
REMOTE
CONTROL
-V
-S
AUXG
RC+
CS
DC OK
RC-
105
18max.
119.2
O/P
1
2
3
4
5
6
Air flow
direction
63.5
3
2
1
I/P
4-M4 L=6
12max.
8.2
63.5
20.75
10
218
32.8152.4
8-M4 L=4 (Both Sides)
32.8
38.312.5
152.4
-20
600W Single Output with PFC Function
File Name:HRPG-600-SPEC 2018-01-15
HRPG-600 series
1
2
9
10
The remote sensing compensates voltage drop on
the load wiring up to 0.5V.
10
10
9
9
CN100
AUX
RC-
GND
GND
-S
AUXG
RC+
CS
DC-OK
+S
2
2
1
1
1.Remote Sense
1
1
9
9
10
10
Sense lines should
be twisted in pairs
LOAD
-
+
+S -S
(Pin9)
(Pin10)
Fig 1.1
Between DC-OK(pin7) and GND(pin6,8)
3.3 ~ 5.6V
0 ~ 1V
Output Status
ON
OFF
DC-OK signal is a TTL level signal. High when PSU turns on.
CN100
AUX
RC-
GND
GND
-S
AUXG
RC+
CS
DC-OK
+S
2.DC-OK Signal
Fig 2.1
CN100
CN100
2
2
5CS
Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance
between units.
7
DC-OK
DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on.
9+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
10 -S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
6,8
GND
This pin connects to the negative terminal(-V). Return for DC-OK signal output.
600W Single Output with PFC Function
File Name:HRPG-600-SPEC 2018-01-15
HRPG-600 series
Function Description of CN100
Pin No. Function
Description
Function Manual
3
4
RC+
RC-
Remote control ground.
Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON.
2
1
AUX
AUXG
Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the
"remote ON/OFF control".
Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).

HRPG-600-15

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 645W 15V 43A W/PFC Function
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: