4
9
7.493 ± 0.254
(0.295 ± 0.010)
10111213141516
87654321
0.457
(0.018)
3.505 ± 0.127
(0.138 ± 0.005)
10.312 ± 0.254
(0.406 ± 0.10)
10.363 ± 0.254
(0.408 ± 0.010)
0.64 (0.025) MIN.
0.203 ± 0.076
(0.008 ± 0.003)
STANDOFF
8.763 ± 0.254
(0.345 ± 0.010)
0-8°
0.457
(0.018)
1.270
(0.050)
A XXXX
YYWW
TYPE NUMBER
DATE CODE
11.63 (0.458)
2.16 (0.085)
0.64 (0.025)
LAND PATTERN RECOMMENDATION
EEE
LOT ID
AVAGO
LEAD-FREE
Dimensions in Millimeters (Inches)
Floating lead protrusion is 0.25 mm (10 mils) Max.
Note: Initial and continued variation in color of the white mold compound is normal and does not aect performance or reliability of the device
ALL LEADS TO
BE COPLANAR
± 0.05 (0.002)
PIN 1 DOT
Package Outline Drawing
16-Lead Surface Mount Package
5
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics
[1]
Description Symbol HCPL-7860 HCPL-786J Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage 300 Vrms
for rated mains voltage 450 Vrms
for rated mains voltage 600 Vrms
for rated mains voltage 1000 Vrms
I - IV
I - III
I - III
I - II
I - IV
I - IV
I - IV
I - III
Climatic Classication 40/85/21 40/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
891 1414 Vpeak
Input to Output Test Voltage, Method b
[2]
V
IORM
x 1.875=V
PR
, 100% Production Test with t
m
=1 sec,
Partial discharge < 5 pC
V
PR
1670 2652 Vpeak
Input to Output Test Voltage, Method a
[2]
V
IORM
x 1.6=V
PR
, Type and Sample Test, t
m
=10 sec,
Partial discharge < 5 pC
V
PR
1425 2262 Vpeak
Highest Allowable Overvoltage(Transient Overvoltage t
ini
= 60 sec) V
IOTM
6000 8000 Vpeak
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current
[3]
Output Power
[3]
T
S
I
S, INPUT
P
S, OUTPUT
175
400
600
175
400
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
>10
9
W
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the applica-
tion. Surface Mount Classications is Class A in accordance with CECC00802.
2. Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Avago Regulatory Guide to Isolation Circuits, AV02-2041EN for a
detailed description of Method a and Method b partial discharge test proles.
3. Refer to the following gure for dependence of P
S
and I
S
on ambient temperature.
OUTPUT POWER - P
S
, INPUT CURRENT - I
S
0
0
T
S
- CASE TEMPERATURE -
o
C
20050
400
12525 75 100 150
600
800
200
100
300
500
700
175
P
S
(mW)
I
S
(mA)
Recommended Pb-Free IR Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The HCPL-7860/HCPL-786J has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 Approved under: DIN EN 60747-5-5(VDE 0884-5):2011-11
UL Approval under UL 1577, component recognition program. File E55361.
CSA Approval under CSA Component Acceptance Notice #5, File CA 88324.
6
Insulation and Safety Related Specications
Option 300 - surface mount classication is Class A in accordance with CECC 00802.
Parameter Symbol DIP-8 SO-16 Units Conditions
Minimum External Air Gap
(Clearance)
L(101) 7.4 8.3 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External Tracking
(Creepage)
L(102) 8.0 8.3 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.5 0.5 mm Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI >175 >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Note
Storage Temperature T
S
-55 125 °C
Ambient Operating Temperature T
A
-40 85 °C
Supply Voltages V
DD1
, V
DD2
0 5.5 V
Steady-State Input Voltage V
IN+
, V
IN-
-2.0 V
DD1
+ 0.5 V 1
Two Second Transient Input Voltage -6.0
Output Voltages MCLK, MDAT -0.5 V
DD2
+ 0.5 V
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Maximum Solder Reow Thermal Prole section
Recommended Operating Conditions
Parameter Symbol Min. Max. Units Note
Ambient Operating Temperature T
A
-40 +85 °C
Supply Voltages V
DD1
, V
DD2
4.5 5.5 V
Input Voltage V
IN+
, V
IN-
-200 +200 mV 1
Electrical Specications (DC)
Unless otherwise noted, all specications are at V
IN+
= 0 V and V
IN-
= 0 V, all Typical specications are at T
A
= 25°C and
V
DD1
= V
DD2
= 5 V, and all Minimum and Maximum specications apply over the following ranges: T
A
= -40°C to +85°C,
V
DD1
= 4.5 to 5.5 V and V
DD2
= 4.5 to 5.5 V.
Parameter Symbol Min. Typ. Max. Units Conditions Fig. Note
Average Input Bias Current I
IN
-0.8 µA 1 3
Average Input Resistance R
IN
450
k W
3
Input DC Common-Mode
Rejection Ratio
CMRR
IN
60 dB 4
Output Logic High Voltage V
OH
3.9 4.9 V I
OUT
= -100 µA
Output Logic Low Voltage V
OL
0.1 0.6 V I
OUT
= 1.6 mA
Output Short Circuit Current |I
OSC
| 30 mA V
OUT
= V
DD2
or GND2
5
Input Supply Current I
DD1
10 15 mA V
IN+
= -350 mV
to +350 mV
2
Output Supply Current I
DD2
10 15 mA 3
Output Clock Frequency f
CLK
8.2 10 13.2 MHz 4
Data Hold Time t
HDDAT
15 ns 6

HCPL-786J#500

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Data Acquisition ADCs/DACs - Specialized Isolated Modulator
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union