BH2227FV, BH2228FV
Technical Note
5/8
www.rohm.com
2011.08 - Rev.B
© 2011 ROHM Co., Ltd. All rights reserved.
●Operation Description
Command Transmission
The Control command consists of 3-lines of 12bit serial input data (MSB first).
Data is read at the rise edge of CLK, and data becomes valid in the CSB Low area (before the CSB rise for 12bit data).
Fig.5
Data Settings
D0 D1 D2 D3 D4 D5 D6 D7 Setting
0 0 0 0 0 0 0 0 GND
1 0 0 0 0 0 0 0 (VDD or VFS-GND)/256x1
0 1 0 0 0 0 0 0 (VDD or VFS-GND)/256x2
1 1 0 0 0 0 0 0 (VDD or VFS-GND)/256x3
0 0 1 0 0 0 0 0 (VDD or VFS-GND)/256x4
~ ~
0 1 1 1 1 1 1 1 (VDD or VFS-GND)/256x254
1 1 1 1 1 1 1 1 (VDD or VFS-GND)/256x255
Note: Initial status D[7:0]=00h
Channel Settings
D8 D9 D10 D11 BH2227FV BH2228FV
0 0 0 0 Inconsequential Inconsequential
0 0 0 1 AO1 AO1
0 0 1 0 AO2 AO2
0 0 1 1 Inconsequential AO3
0 1 0 0 Inconsequential AO4
0 1 0 1 AO3 AO5
0 1 1 0 AO4 AO6
0 1 1 1 Inconsequential Inconsequential
1 0 0 0 Inconsequential Inconsequential
1 0 0 1 Inconsequential Inconsequential
1 0 1 0 Inconsequential Inconsequential
1 0 1 1 Inconsequential Inconsequential
1 1 0 0 Inconsequential Inconsequential
1 1 0 1 Inconsequential Inconsequential
1 1 1 0 Inconsequential Inconsequential
1 1 1 1 Inconsequential Inconsequential
D0 D1
CSB
CLK
DI
D2D3D4D5D6D7D8 D9 D10 D11 X X
1 23456789 10 11 12