JCK2024S12

DCDC
Specification
20 Watts
2:1 Input Range
40 °C to +100 °C Operating Temperature
Single & Dual Outputs
Remote On/Off
High Efficiency up to 93%
1600 VDC Isolation
3 Year Warranty
JCK Series
Input
Input Voltage Range 12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-75 VDC)
Input Current See table
Undervoltage Lockout 12 V models: ON 8.6 V, OFF 7.9 V typical
24 V models: ON 17.8 V, OFF 16 V typical
48 V models: ON 33.5 V, OFF 30.5 V typical
Input Surge 12 V models 36 VDC for 100 ms
24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Output
Output Voltage See table
Output Voltage Trim ±10% max on single outputs
Minimum Load No minimum load required
Line Regulation ±0.5% max
Load Regulation Single output models: ±0.5% max
Dual output models: ±1% max
balanced outputs
Cross Regulation ±5% for dual outputs (see note 2)
Setpoint Accuracy ±1% max
Start Up Delay <20 ms
Start Up Rise Time <5 ms
Ripple & Noise 75 mV pk-pk (see note 3)
Transient Response ±3% max deviation, recovery to within
1% in 250 µs for a 25% load change
Temperature 0.02%/°C
Coefficient
Overvoltage Protection 3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
±12 V models: ±15 V typical
±15 V models: ±18 V typical
Overload Protection >140% of full load at nominal input
Short Circuit Protection Trip & restart (hiccup mode), auto recovery
Remote On/Off On = Logic High (>3.0 V) or Open
Off = Logic Low (<1.2 V) or short pin 2 to
pin 6
Capacitive Load See table
xppower.com
General
Efficiency See table
Isolation 1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
Isolation Capacitance 1200 pF typical
Isolation Resistance 10
9
min
Switching Frequency 330 kHz typical
Power Density 25 W/in
3
MTBF >680 kHrs minimum to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature -40 °C to +100 °C, derate from 100% load
at +70 °C to 0% load at +100 °C
Case Temperature +100 °C max
Cooling Convection-cooled
Operating Humidity Up to 95% RH, non-condensing
Storage Temperature -40 °C to +125 °C
EMC
Emissions EN55022, Class A conducted
& radiated with external components,
see application note
ESD Immunity EN61000-4-2, 8 kV air, 6 kV contact,
Perf Criteria A
Radiated Immunity EN61000-4-3 10 V/m, Perf Criteria A
EFT/Burst EN61000-4-4 level 3, Perf Criteria B*
Surge EN61000-4-5 level 2, Perf Criteria B*
Conducted Immunity EN61000-4-6 10 V/rms,Perf Criteria A
Magnetic Field EN61000-4-8 1 A/m, Perf Criteria A
*External input capacitor required 220 µF/100 V.
01-Aug-13
DC/DC
Converter
+Vin +Vout
LOAD
C1
+
-
12 µH
-Vin -Vout
C1 = 330 µF
C1 = 220 µF
12 Vin:
24 & 48 Vin:
DCDC
JCK20
Models and Ratings
I
nput
V
oltage
O
utput
V
oltage
O
utput
C
urrent
I
nput Current
(
1)
Maximum
C
apacitive Load
E
fficiency
M
odel
N
umber
No Load Full Load
9
-18 VDC
3.3 VDC 5.500 A 60 mA 1.74 A 10,000 µF 90% JCK2012S3V3
5.0 VDC 4.000 A 60 mA 1.87 A 6,800 µF 92% JCK2012S05
12.0 VDC 1.670 A 30 mA 1.92 A 1,000 µF 90% JCK2012S12
15.0 VDC 1.330 A 30 mA 1.92 A 680 µF 90% JCK2012S15
±12.0 VDC ±0.835 A 30 mA 1.94 A ±470 µF 89% JCK2012D12
±15.0 VDC ±0.665 A 30 mA 1.94 A ±330 µF 89% JCK2012D15
18-36 VDC
3.3 VDC 5.500 A 35 mA 0.86 A 10,000 µF 91% JCK2024S3V3
5.0 VDC 4.000 A 35 mA 0.93 A 6,800 µF 93% JCK2024S05
12.0 VDC 1.670 A 25 mA 0.95 A 1,000 µF 91% JCK2024S12
15.0 VDC 1.330 A 25 mA 0.95 A 680 µF 91% JCK2024S15
±
12.0 VDC
±
0.835 A
3
0 mA
0
.96 A
±
470 µF
9
0%
J
CK2024D12
±
15.0 VDC
±
0.665 A
3
0 mA
0
.96 A
±
330 µF
9
0%
J
CK2024D15
36-75 VDC
3
.3 VDC
5
.500 A
2
5 mA
0
.43 A
1
0,000 µF
9
1%
J
CK2048S3V3
5
.0 VDC
4
.000 A
2
5 mA
0
.46 A
6
,800 µF
9
3%
J
CK2048S05
1
2.0 VDC
1
.670 A
1
5 mA
0
.47 A
1
,000 µF
9
1%
J
CK2048S12
1
5.0 VDC
1
.330 A
1
5 mA
0
.47 A
6
80 µF
9
1%
J
CK2048S15
±12.0 VDC ±0.835 A 20 mA 0.48 A ±470 µF 90% JCK2048D12
±15.0 VDC ±0.665 A 20 mA 0.48 A ±330 µF 89% JCK2048D15
Notes
1. Input current specified at nominal 12, 24 V or 48 V input.
2
. Cross regulation is ±5% when one output is at 100% and the other is varied
b
etween 25% and 100%.
3. Measured with 20 MHz bandwidth and 1 µF ceramic capacitor across output rails.
4
. For heatsink option add ‘-HK’ to the end of the part number.
53 4
21
0.40
(10.2)
Ø 0.02
(0.5)
Ø 0.04
(1.0)
Ø 0.04
(1.0)
0.20
(5.0)
0.40
(10.16)
0.40
(10.1)
0.60
(15.2)
0.60
(
15.2)
0.80
(20.3)
0.20
(5.08)
0.20
(5.0) min.
0.10
(
2.5)
0.40
(10.1)
0.40
(10.1)
0.10
(
2.5)
Bottom View
6
0.20
(5.0)
2.00
(50.8)
1
.00 (25.4)
2.00
(50.8)
Thermal Pad
Optional heatsink (-HK)
0
.64
(16.3)
Mechanical Details
Application Notes
50%
25%
75%
100%
-40 -20 0 20 40 60 80 100 120
85
70 75
Ambient Temperature (
°C
)
Output Power
without heat-sink
with heat-sink
Derating Curve
External Output Trim
TRIM UP
4
5
TRIM DOWN
3
4
PIN CONNECTIONS
Pin Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 +Vout +Vout
4 Trim Com
5 -Vout -Vout
6 Remote On/Off Remote On/Off
Remote On/Off Control
Output On >3.0 VDC or open circuit
Output Off <1.2 VDC or short circuit pins 2 & 6
Notes
1. All dimensions are in inches (mm).
2. Weight: 0.07 lbs (30 g)
3. Pin diameter: 0.04 ±0.002 (1.0 ±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
Input Filter
For 3.3 V output:
Trim +10%, R = 10 k typical
Trim - 10%, R = 15 k typical
For 5 V output:
Trim +10%, R = 10 k typical
Trim - 10%, R = 5 k typical
For 12 V output:
Trim +10%, R = 22 k typical
Trim - 10%, R = 5 k typical
For 15 V output:
Trim +10%, R = 20 k typical
Trim - 10%, R = 5 k typical

JCK2024S12

Mfr. #:
Manufacturer:
Description:
DC DC CONVERTER 12V 20W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union