TLP291
2014-09-22
10
EN 60747-5-5 Option:(V4)
Types : TLP291
Type designations for “option: (V4)”, which are tested under EN 60747 requirements.
(e.g.): TLP291 (V4GB-TP,E V4 : EN 60747 option
GB : CTR rank type
TP : Standard tape & reel type
E : `G`/RoHS COMPATIBLE (Note4 )
Note: Use TOSHIBA standard type number for safety standard application.
(e.g.): TLP291(V4GB-TP,E TLP291
Note4: Please contact your Toshiba sales representative for details on environmental information such
as the product’s RoHS compatibility.
RoHS is the Directive 2002/95/EC of the European Parliament and of the Council of 27
January 2003 on the restriction of the use of certain hazardous substances in electrical and
electronics equipment.
EN 60747 Isolation Characteristics
Description Symbol Rating Unit
Application classification
for rated mains voltage 150Vrms
for rated mains voltage 300Vrms
I-IV
I-III
-
Climatic classification
55 / 110 / 21 -
Pollution degree
2 -
Maximum operating insulation voltage V
IORM
707 Vpk
Input to output test voltage, Method A
Vpr=1.5 × V
IORM
, type and sample test
tp=10s, partial discharge<5pC
V
pr
1060 Vpk
Input to output test voltage, Method B
Vpr=1.875 × V
IORM
, 100% production test
tp=1s, partial discharge<5pC
V
pr
1325 Vpk
Highest permissible overvoltage
(transient overvoltage, tpr=60s)
V
TR
6000 Vpk
Safety limiting values (max. permissible ratings in case of fault,
also refer to thermal derating curve)
current (input current: I
F
, Psi=0mW)
power (output or total power dissipation)
temperature
I
si
P
si
T
si
250
400
150
mA
mW
°C
Insulation resistance
V
IO
=500V, Ta=T
si
R
si
10
9
Ω