1841A 0101000

Part Number: 1841A
DBS Cable, Dual RG6, 18 AWG BCCS, Foil + Braid, CM
Product Description
Series 6 (RG6/U type Dual Coax), 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, Al. braid
shield (60% coverage), PVC jacket.
Technical Specifications
Product Overview
Environmental Space: Indoor (Not Riser or Plenum)
Physical Characteristics (Overall)
Conductor
AWG Stranding Material Nominal Diameter No. of Coax
18 Solid
BCCS - Bare Copper Covered
Steel
0.04 in 2
Conductor Count: 2
Conductor Size: 18 AWG
Insulation
Material Nominal Diameter
Gas-injected FPE - Foam Polyethylene 0.18 in
Outer Shield Material
Type Layer Material Material Trade Name Coverage [%]
Tape 1 Aluminum/Polyester/Aluminum Bonded Duofoil® 100 %
Braid 2 AL - Aluminum 60 %
Outer Jacket Material
Material Nominal Diameter
PVC - Polyvinyl Chloride 0.273 x 0.595 in
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR
28 Ohm/1000ft 9 Ohm/1000ft 9 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
16.2 pF/ft
Shielding: Multiple or Specialty
Inductance
Nominal Inductance
0.097 µH/ft
Impedance
Nominal Characteristic Impedance
75 Ohm
Return Loss (RL)
Frequency [MHz] Min. Structural Return Loss (SRL)
950 - 2250 MHz 15 dB
2250 - 3000 MHz 10 dB
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
5 MHz 0.5 dB/100ft
55 MHz 1.4 dB/100ft
211 MHz 2.6 dB/100ft
500 MHz 4.1 dB/100ft
750 MHz 5.1 dB/100ft
862 MHz 5.5 dB/100ft
1000 MHz 6 dB/100ft
1450 MHz 7.8 dB/100ft
1800 MHz 8.6 dB/100ft
2250 MHz 9.8 dB/100ft
3000 MHz 11.3 dB/100ft
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.2 ns/ft 83 %
High Freq
Frequency [MHz] Max. Insertion Loss (Attenuation)
5 MHz 0.58 dB/100ft
55 MHz 1.6 dB/100ft
211 MHz 3.05 dB/100ft
500 MHz 4.66 dB/100ft
750 MHz 5.65 dB/100ft
862 MHz 6.1 dB/100ft
1000 MHz 6.55 dB/100ft
1450 MHz 8 dB/100ft
1800 MHz 8.8 dB/100ft
2250 MHz 10 dB/100ft
3000 MHz 11.9 dB/100ft
Voltage
Non-UL Voltage Rating
350 V RMS
Temperature Range
Non-UL Temp Rating: 80°C
Operating Temp Range: -40°C To +80°C
Mechanical Characteristics
Bulk Cable Weight: 56 lbs/1000ft
Max Recommended Pulling Tension: 252 lbs
Min Bend Radius/Minor Axis: 3 in
Standards
NEC/(UL) Specification: CATV, CM
CEC/C(UL) Specification: CM
RG Type: 6/U Type
Series Type: Series 6
RG / Series Type: Series 6
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU: Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: No
EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Indoor: Yes
Flammability, LS0H, Toxicity Testing
UL Flammability: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Part Number
Variants
Item # Color Footnote
1841A 0101000 Black C
Footnote: C - CRATE REEL PUT-UP.
© 2018 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.

1841A 0101000

Mfr. #:
Manufacturer:
Belden Wire \u0026 Cable
Description:
Coaxial Cables 2 #18 GIFHDLDPE SH FR PVC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet