Page 4 ams Datasheet
Document Feedback [v1-00] 2016-May-30
TSL250R, TSL251R, TSL252R − Absolute Maximum Ratings
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. These are stress
ratings only. Functional operation of the device at these or any
other conditions beyond those indicated under Recommended
Operating Conditions is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Figure 5:
Absolute Maximum Ratings Over Operating Free-Air Temperature Range (unless otherwise noted)
Note(s):
1. All voltages are with respect to GND.
2. Output may be shorted to supply.
Symbol Parameter Min Max Unit
V
DD
Supply voltage
(1)
6V
I
O
Output current ±10 mA
Duration of short-circuit current at (or below) 25°C
(2)
5s
T
A
Operating free-air temperature range -25 85 °C
T
STRG
Storage temperature range -25 85 °C
Lead temperature 1.6mm (1/16 inch) from case for 10 seconds
(S Package)
260 °C
Reflow solder, in accordance with J-STD-020C or J-STD-020D
(SM Package)