DC and AC parameters M48Z02, M48Z12
14/22 Doc ID 2420 Rev 9
4 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Table 6:
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Table 6. Operating and AC measurement conditions
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 9. AC testing load circuit
Table 7. Capacitance
Parameter M48Z02 M48Z12 Unit
Supply voltage (V
CC
) 4.75 to 5.5 4.5 to 5.5 V
Ambient operating temperature (T
A
) Grade 1 0 to 70 0 to 70 °C
Load capacitance (C
L
) 100 100 pF
Input rise and fall times ≤ 5 ≤ 5ns
Input pulse voltages 0 to 3 0 to 3 V
Input and output timing ref. voltages 1.5 1.5 V
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V. Sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance - 10 pF
C
IO
(3)
3. Outputs deselected.
Input / output capacitance - 10 pF
AI01019
5V
OUT
C
L
= 100pF
C
L
includes JIG capacitance
1.8kΩ
DEVICE
UNDER
TEST
1kΩ