1. SCOPE
This specification covers the requirements for one type of low fire hazard, electrically insulating, extruded tubing
whose diameter will reduce to a predetermined size upon the application of heat in excess of 120C. It is suitable for
use with Hot Melt Adhesive Tape S1030 or Flame-Retardant Mastic Tape S1305.
2. REQUIREMENTS
2.1 Composition and Appearance
The tubing shall be fabricated from thermally stabilized, flame-retardant modified polyolefin and shall be irradiation
crosslinked. It shall be homogeneous and essentially free from flaws, defects, pinholes, bubbles, seams, cracks and
inclusions. It shall contain essentially no halogens.
2.2 Color
The tubing color shall be black.
3. PROPERTIES
The tubing shall meet the requirements of Tables 1 and 2.
4. QUALITY ASSURANCE PROVISIONS
4.1 Classification of Tests
4.1.1 Qualification Tests
Qualification tests are those performed on the tubing submitted for qualification as a satisfactory product and shall
consist of all the tests listed in this specification.
4.1 .2 Production Routine Tests
Production routine tests shall be carried out on every batch, unless otherwise specified and shall consist of the
following: dimensions, longitudinal change, tensile strength, ultimate elongation, low temperature flexibility and
flammability.
5. SAMPLING INSTRUCTIONS
5.1 Qualification Test Samples
Qualification test samples shall consist of 45 m (150 feet) of tubing. Qualification of size 15 or 20 qualifies all sizes.
The color shall be black.
5.2 Production Routine Test Samples
Production routine test samples shall consist of a sufficient length to perform all the tests in 4.1.2 selected at random
from each batch. A batch shall consist of all tubing of the same size, from the same production run and offered for
inspection at the same time. Physical property tests performed at this time qualify subsequent tubing lots produced
from the same compound batch.
6. TEST PROCEDURES
Unless otherwise specified the tubing shall be recovered in a forced air circulating oven for 10 minutes at 150 2C.
6.1 Dimensions and Longitudinal Change
The test method shall be as specified in ASTM D 2671.
The length and inside diameter of three 250 mm (10 inch) long specimens of expanded tubing shall be measured. The
specimens shall be recovered and the length and inside diameter of each shall be measured. The longitudinal change
shall be expressed as a percentage of the original length. The minimum and maximum recovered wall thicknesses shall
be determined.
Page 2 SPECIFICATION RW-2016 ISSUE 9
© 2008-2014 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check the latest revision.
6.2 Tensile Strength and Ultimate Elongation
The test method shall be as specified in ASTM D 638.
For tubing of recovered inside diameter greater than 6.0 mm (0.236 inch), five Type IV dumbbell specimens shall be
tested. For tubing of recovered inside diameter less than or equal to 6.0 mm (0.236 inch), five tubular specimens
150 mm (6 inches) long shall be tested. Rate of jaw separation shall be 500 10 mm (20 0.5 inches) per minute.
The test shall be carried out at a temperature of 23 2C.
6.3 Halogen Content
Determine the halogen content (fluorine, chlorine and bromine) of tubing by any suitable elemental analysis technique
capable of measuring each halogen to 50 ppm or all three halogens together to 100 ppm.
7. PREPARATION FOR DELIVERY
7.1 Form
The tubing shall be supplied in cut lengths unless otherwise specified.
7.2 Packaging
Packaging shall be in accordance with good commercial practice.
7.3 Marking
Each container of tubing shall be permanently and legibly marked with the size, quantity, manufacturer's identification
and batch number.
8. APPLICABLE DOCUMENTS
This specification takes precedence over documents referenced herein. Unless otherwise specified, the latest issue of
referenced documents applies. The following documents form a part of this specification to the extent specified herein.
8.1 GOVERNMENT FURNISHED DOCUMENTS
Military
MIL-H-5606 Hydraulic Fluid, Petroleum Base, Aircraft, Missile and Ordnance
MIL-DTL-83133 Turbine Fuel, Aviation, Grade JP-8
MIL-C-24643 Cable and Cords Electrical Low Smoke for Shipboard Use, General Specification
NES 711 Determination of the Smoke Index of the Products of Combustion from Small Specimens of
Material
NES 713 Determination of the Toxicity Index of the Products of Combustion from Small Specimens of
Material
8.2 OTHER PUBLICATIONS
American Society for Testing and Materials (ASTM)
ASTM D 570 Standard Test Method for Water Absorption
ASTM D 638 Standard Test Methods for Tensile Properties of Plastics
ASTM D 792 Standard Test Methods for Specific Gravity (Relative Density) and Density of Plastic
by Displacement
ASTM D 876 Standard Test Methods for Non Rigid Vinyl Chloride Polymer Tubing Used for Electrical
Insulation
ASTM D 2671 Standard Methods of Testing Heat-Shrinkable Tubing for Electrical Use
SPECIFICATION RW-2016 ISSUE 9 Page 3
© 2008-2014 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check the latest revision.
ASTM D 2863 Test Method for Measuring Minimum Oxygen Concentration to Support Candle-Like
Combustion of Plastics (Oxygen Index)
(Copies of ASTM publications may be obtained from the American Society for Testing and Materials,
1916 Race Street Philadelphia, Pennsylvania 19103 or via the ASTM website at http://www.astm.org).
International Organization for Standardization (ISO)
ISO 846 Method B Plastics – Evaluation of the Action of Microorganisms
(Copies of ISO publications may be obtained from the International Organization for Standardization,
1, rue de Varembé, CH-1211 Geneva 20, Switzerland or via the ISO website at
http://www.iso.ch/iso/en/ISOOnline.frontpage)
SAE International
SAE-AMS-DTL-23053 Insulating Tubing, Electrical, Heat Shrinkable, General Specification
(Copies of SAE publications may be obtained from SAE International, 400 Commonwealth Drive, Warrendale, PA
15096-0001 or via the SAE website at http://www.sae.org.)
TABLE 1
TUBING DIMENSIONS
Internal Diameter, mm (inch) Wall Thickness, mm (inch)
Size
(Min.) Expanded
as Supplied
(Max.) Recovered After
Heating
(Nom.) Recovered
After Heating
-03 7.62 (0.300) 2.54 (0.100) 2.03 (0.080)
-04 10.16 (0.400) 3.81 (0.150) 2.03 (0.080)
-07 19.05 (0.750) 5.59 (0.220) 2.03 (0.080)
-11 27.94 (1.100) 9.53 (0.375) 2.79 (0.110)
-15 38.10 (1.500) 12.70 (0.500) 3.05 (0.120)
-20 50.80 (2.000) 19.05 (0.750) 3.05 (0.120)
-30 76.20 (3.000) 31.75 (1.250) 4.06 (0.160)
-40 101.60 (4.000) 44.45 (1.750) 4.06 (0.160)