AWM5103VN

Interactive Catalog Replaces Catalog Pages
Sensing and Control
Honeywell Inc.
11 West Spring Street
Freeport, Illinois 61032
Honeywell Sensing and Control has replaced
the PDF product catalog with the new
Interactive Catalog. The Interactive Catalog is
a power search tool that makes it easier to find
product information. It includes more
installation, application, and technical
information than ever before.
Click this icon to try the new
Interactive Catalog.
Airflow Sensors AWM5000 Series
High Flow Mass Airflow/Amplified
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
79
In-Line Flow Measurement
AWM5000 Series Microbridge Mass Air-
flow Sensors feature a venturi type flow
housing. They measure flow as high as 20
standard liters per minute (SLPM) while
inducing a maximum pressure drop of
2.25N H
2
O. The microbridge chip is in di-
rect contact with the flow stream, greatly
reducing error possibilities due to orifice
or bypass channel clogging.
Rugged, Versatile Package
The rugged plastic package has been
designed to withstand common mode
pressures up to 50 psi, and the small
sensing element allows 100 gs of shock
without compromising performance. The
included ‘‘AMP’’ compatible connector
provides reliable connection in demand-
ing applications.
On-board Signal Conditioning
Each AWM5000 sensor contains circuitry
which performs amplification, lineariza-
tion, temperature compensation, and gas
calibration. Figure 1 (Heater Control Cir-
cuit) and Figure 2 (Sensor Bridge Circuit
and Amplification Linearization Circuit) il-
lustrate the on-board electrical circuitry
for the AWM5000 Series. A 1 to 5 VDC
linear output is possible for all listings
regardless of flow range (5, 10, 15, or 20
SLPM) or calibration gas (nitrogen, car-
bon dioxide, nitrous oxide, or argon). All
calibration is performed by active laser
trimming.
FEATURES
1 Linear voltage output
1 Venturi design
1 Remote mounting capability
1 Active laser trimming improves inter-
change ability
1 Separate gas calibration types:
– Ar (argon)
– N
2
(nitrogen) or
– CO
2
(carbon dioxide)
Figure 1
Figure 2
Airflow
Airflow Sensors AWM5000 Series
Highflow Mass Airflow/Amplified
80
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
SPECIFICATIONS (Performance Characteristics @ 10.0 ±0.01 VDC, 25°C)
AWM5101 AWM5102 AWM5103 AWM5104
Flow Range (Note 3) 0-5 SLPM 0-10 SLPM 0-15 SLPM 0-20 SLPM
Suffix - Calibration gas VA - Argon (Ar) VC - Carbon dioxide (CO
2
) VN - Nitrogen (N
2
)
Min. Typ. Max.
Excitation VDC 8 10±0.01 15
Power consumption (mW) 100
Response time (msec) 60
Null output VDC 0.95 1 1.05
Null output shift
20° to 70°C— ±0.050 VDC ±.200 VDC
Common Mode
Pressure (psi) 50
Temperature range 20° to +70°C, (4° to 158°F)
Weight 60 grams (2.12 oz.)
Shock ratings 100 g peak, 6 msec half-sine (3 drops, each direction of 3 axes)
Output @ laser trim point 5 VDC @ Full Scale Flow
Output voltage shift
+20° to 25°C, +20° to 70°C Suffix VA or VN ±7.0% Reading, Suffix VC ±10.0% Reading
Linearity error (2) ±3.0% Reading (max.)
Repeatability & Hysteresis ±0.5% Reading (max.)
Connector (Included)
—Four pin receptacle MICRO SWITCH (SS12143)/AMP (103956-3)
Leak rate, max 0.1 psi/min. at static condition, (Note 2)
Notes:
1. Linearity specification applies from 2 to 100% full scale of gas flow range, and does not apply to null output at 0 SLPM.
2. The AWM5000 series product has a leakage spec of less than 0.1 psi per minute at 50 psi common mode pressure. If during installation, the
end adapters are twisted with respect to the flowtube, this may compromise the seal between the o-ring and the flowtube and may cause a
temporary leak. This leak might be as high as 1 psi or might remain in specification. It will self-reseal as the o-ring takes a new set.
Approximately 85% of the leakage will dissipate in 24 hours. Within 48 hours, complete recovery will take place.
3. SLPM denotes standard liters per minute, which is a flow measurement referenced to standard conditions of 0°C/1 bar (sea level), 50% RH.
NOTICE
AWM5000Chimney Effect
AWM microbridge mass airflow sensors detect mass airflow caused by heat transfer. The thermally isolated
microbridge structure consists of a heater resistor positioned between two temperature sensing resistors.
The heater resistor maintains a constant temperature, 160°C above ambient, during sensor operation. Airflow
moving past the chip transfers heat from the heater resistor. This airflow warms the downstream resistor and
cools the upstream resistor. The temperature change and the resulting change in resistance of the
temperature resistors is proportional to the mass airflow across the sensing element.
When the sensor is mounted in a vertical position, under zero flow conditions, the sensor may produce an
output that is the result of thermally induced convection current. This occurrence is measurable in the
AWM5000 Series, particularly in the 5 SLPM versions. When designing the sensor into applications where null
stability is critical, avoid mounting the sensor in a vertical position.

AWM5103VN

Mfr. #:
Manufacturer:
Description:
Flow Sensors 0 L/min to 15 L/min Airflow Sensors
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet