HIH-5031-001S

4 www.honeywell.com/sensing
Figure 3. Typical Output Voltage vs Relative Humidity (At 25 °C and 3.3 Vdc.)
0
20
40 60 80 100
0.5
1
2
2.5
3
1.5
Relative Humidity (%RH)
Output Voltage (Vdc)
Rising RH
Falling RH
Figure 4. Typical Output Voltage (BFSL) vs Relative Humidity (At 0 C, 70 C and 3.3 Vdc.)
0
20
40 60 80 100
0.5
1
2
2.5
3
1.5
Relative Humidity (%RH)
Output Voltage (Vdc)
70° C
0° C
Honeywell Sensing and Control 5
Figure 5. HIH-5030 Mounting Dimensions (For reference only. mm/[in])
2,54
[0.100]
0.57
[0.226]
1,27
[0.050]
2,54
[0.100]
3X 0,38
[0.015]
4,17 ±0,05
[0.164 ±0.002]
-ve
OUT
+ve
0,71
[0.028]
2,27 ±0,05
[0.090 ±0.002]
8,59 ±0,05
[0.338 ±0.002]
2,67
[0.105]
0,41
[0.016]
1,22
[0.048]
2,62
[0.103]
2,95
[0.116]
1,78
[0.070]
Figure 6. HIH-5030 PCB Landing Pattern (For reference only. mm/[in])
2X 1,27
[0.05]
3X 0,51
[0.02]
8,89
[0.35]
1,78
[0.07]
2,29
[0.09]
2,54
[0.10]
PCB LANDING PATTERN
6 www.honeywell.com/sensing
Figure 7. HIH-5031 Mounting Dimensions (For reference only. mm/[in])
2,54
[0.100]
0.57
[0.226]
1,27
[0.050]
2,54
[0.100]
3X 0,38
[0.015]
4,17 ±0,05
[0.164 ±0.002]
-ve
OUT
+ve
0,71
[0.028]
2,27 ±0,05
[0.090 ±0.002]
8,59 ±0,05
[0.338 ±0.002]
2,67
[0.105]
0,41
[0.016]
1,22
[0.048]
2,62
[0.103]
2,95
[0.116]
FILTER
1,78
[0.070]
Figure 8. HIH-5031 PCB Landing Pattern (For reference only. mm/[in])
2X 1,27
[0.05]
3X 0,51
[0.02]
8,89
[0.35]
1,78
[0.07]
2,29
[0.09]
2,54
[0.10]
PCB LANDING PATTERN

HIH-5031-001S

Mfr. #:
Manufacturer:
Description:
Board Mount Humidity Sensors HyCal Sensing Produc 3600 Series CMOS Sen
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet