MTU1D1215MC-R

MTU1 Series
Isolated 1W Single & Dual Output SM DC/DC Converters
KDC_MTU.C02 Page 1 of 8
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
SELECTION GUIDE
Order Code
1
Nominal Input
Voltage
Output
Voltage
Output Current
Load Regulation
(Typ.)
Load Regulation
(Max)
Ripple & Noise
(Typ.)
3
Ripple & Noise
(Max.)
3
Input Current at
Full Load
Efficiency (Min.)
Efficiency (Typ.)
Isolation
Capacitance
MTTF
2
VVmA
% mVp-p
mA % % pF kHrs
MTU1S0305MC 3.3 5 200 8.9 11.0 26 60 367 79 81 14 7660
MTU1S0505MC 5 5 200 7.3 9 35 60 241 80 83 19 5664
MTU1S0509MC 5 9 111 6.1 7.5 15 25 233 83 86 20 5488
MTU1S0512MC 5 12 83 5.6 7.5 15 25 230 84 87 21 5186
MTU1S0515MC 5 15 67 5.3 6.5 15 25 230 84 87 22 4773
MTU1S1205MC 12 5 200 5.6 8 20 40 99 80 84 22 5641
MTU1S1209MC 12 9 111 3.9 6 15 25 96 82 87 31 5467
MTU1S1212MC 12 12 83 3.5 6 10 25 95 83 88 40 5165
MTU1S1215MC 12 15 67 3.2 5
10 25
95 84 88 35 4753
MTU1D0305MC 3.3 ±5 ±100 8.0 9.5
18 35
356 80 83 17 5292
MTU1D0505MC 5 ±5 ±100 6.6 8
14 30
235 81 84 18 5053
MTU1D0509MC 5 ±9 ±56 5.6 6.5 7 20 229 83 86 21 5078
MTU1D0512MC 5 ±12 ±42 5.0 6 8 20 228 83 87 19 5545
MTU1D0515MC 5 ±15 ±33 5.1 6.5 8 20 224 84 88 22 5293
MTU1D1205MC 12 ±5 ±100 4.3 5 14 30 98 80 85 18 4335
MTU1D1209MC 12 ±9 ±56 3.1 4 7 20 95 82 87 27 4601
MTU1D1212MC 12 ±12 ±42 3.0 4 8 20 94 84 88 35 4834
MTU1D1215MC 12 ±15 ±33 2.6 3.5 8 20 94 84 88 35 4782
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
Continuous operation, 3.3V input types 2.97 3.3 3.63
V
Continuous operation, 5V input types 4.5 5.0 5.5
Continuous operation, 12V input types 10.8 12.0 13.2
Reflected ripple current
Single output types
3.3V input types 10
mA p-p
5V input types 6
12V input types 5
Dual output types All variants 5
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation voltage Flash tested for 1 second 1000 VDC
Resistance Viso= 1000VDC 10 GΩ
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Switching frequency
MTU1D0305MC 70
kHz
3.3V & 5V input, all output types
(except MTU1D0305MC)
82
12V input, single output types 90
12V intput, dual output types 100
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated power TA=-40°C to 85°C 1.0 W
Voltage set point accuracy
See tolerance envelope
Line regulation High V
IN to low VIN 1.0 1.1 %/%
1. If components are required in tape and reel format suffix order code with -R, e.g. MTU10505MC-R.
2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load.
3. See ripple & noise characterisation method.
All specifications typical at T
A=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
Patent Protected
UL60950 recognised
Footprint over pins 0.69cm
2
Single & dual isolated output
1kVDC Isolation “Hi Pot Test”
Efficiency up to 88% (Typ.)
MSL Level 1
Power density 1.71W/cm
3
Wide temperature performance at full
1 Watt load, –40°C to 85°C
UL 94V-0 Package material
3.3V, 5V & 12V Input
5V, 9V, 12V & 15V single & dual outputs
Toroidal magnetics
Custom solutions available
Multi-layer ceramic capacitors
PRODUCT OVERVIEW
The MTU1 series is a new range of miniature
surface mount, high performance 1W DC/DC
converters. With a footprint reduction of over 50%
from the previous generation of 1W SMD DC/DC,
the MTU1 series offers 1W of available output
power over the full industrial temperature range of
-40ºC to 85ºC. The MTU1 series is more efficient
and offers improved regulation performance for
applications where a wide output voltage variation
can not be tolerated.
The devices are suitable for all applications where
high volume production is envisaged.
MTU1 Series
Isolated 1W Single & Dual Output SM DC/DC Converters
KDC_MTU.C02 Page 2 of 8
www.murata-ps.com/support
ABSOLUTE MAXIMUM RATINGS
Input voltage VIN, MTU1S03 types 5.5V
Input voltage V
IN, MTU1S05 types 7V
Input voltage V
IN, MTU1S12 types 15V
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification All output types -40 85
°C
Storage -55 125
Case temperature rise above ambient
1
MTU1xxx05MC 15
MTU1xxx09MC 14
MTU1xxx12MC & MTU1xxx15MC
11
Cooling Free air convection
1. Measured after 1 hour continuous operation at nominal VIN full load at the center of each PCB.
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Volt-
age’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation,
to verify the integrity of that isolation.
Murata Power Solutions MTU1 series of DC/DC converters are all 100% production tested
at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied
across the part in normal operation?”
The MTU1 has been recognized by Underwriters Laboratory for functional insulation, both
input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient
voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied
continuously across the isolation barrier; but then the circuitry on both sides of the bar-
rier must be regarded as operating at an unsafe voltage and further isolation/insulation
systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can
actually degrade isolation capability, to a lesser or greater degree depending on materi-
als, construction and environment. The MTU1 series has toroidal isolation transformers,
with no additional insulation between primary and secondary windings of enameled
wire. While parts can be expected to withstand several times the stated test voltage,
the isolation capability does depend on the wire insulation. Any material, including this
enamel (typically polyurethane) is susceptible to eventual chemical degradation when
subject to very high applied voltages thus implying that the number of tests should be
strictly limited. We therefore strongly advise against repeated high voltage isolation test-
ing, but if it is absolutely required, that the voltage be reduced by 20% from specified
test voltage.
This consideration equally applies to agency recognized parts rated for better than func-
tional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MTU1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation to a maximum product PCB temperature of 120°C. Forced air cooling
may be used to maintain this temperature requirement. File number E151252 applies.
The MTU1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
MTU1X03xxxC: 0.750A
MTU1X05xxxC: 0.125A
MTU1X12xxxC: 0.315A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
MTU1 Series
Isolated 1W Single & Dual Output SM DC/DC Converters
KDC_MTU.C02 Page 3 of 8
www.murata-ps.com/support
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak reflow
solder temperature of 245ºC as per J-STD-020D.1.
The pin termination finish on this product series is Matte Tin over Nickel
Preplate. The series is backward compatible with Sn/Pb soldering systems.
The series has a Moisture Sensitivity Level (MSL) 1.
Samples of the product series were tested in accordance with the condition-
ing described for MSL level 1 in IPS/J-STD-020D.1.
The product series passed electrical tests and visual inspection criteria.
For further information, please visit: www.murata-ps.com/rohs
TEMPERATURE DERATING GRAPH
150100
50
0
-40
0
0.5
1.0
1.5
Safe Operating Area
85°C
Ambient Temperature (°C)
Output Power (W)
TOLERANCE ENVELOPES
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading and set point accuracy.
Output Load Current (%)
egatl
oV tu
ptuO
VNOM
6%
0%
-4%
1.5%
100
75
50
25
10
Single 5V output types (except 3.3V input)
Output Load Current (%)
egatlo
V tuptuO
VNOM
5%
0%
-4%
1%
100
75
50
25
10
Output Load Current (%)
egatlo
V tuptuO
4%
9%
0%
-4%
1%
100
75
50
25
10
3.3V Input Types
All other types
Output Load Current (%)
egatlo
V tuptuO
2%
7%
0%
-4%
1%
100
75
50
25
10
Dual 5V Output types (except 3.3V input)

MTU1D1215MC-R

Mfr. #:
Manufacturer:
Murata Power Solutions
Description:
Isolated DC/DC Converters 1W 12Vin 15Vout 33mA Dual SMT
Lifecycle:
New from this manufacturer.