STP36NF06 - STP36NF06FP Electrical ratings
3/14
1 Electrical ratings
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
TO-220 TO-220FP
V
DS
Drain-source voltage (V
GS
= 0) 60 V
V
GS
Gate- source voltage ± 20 V
I
D
Drain current (continuous) at T
C
= 25°C 30 18
(1)
1. Current limited by package’s thermal resistance
A
I
D
Drain current (continuous) at T
C
= 100°C 21 12
(1)
A
I
DM
(2)
2. Pulse width limited by safe operating area.
Drain current (pulsed) 120 72 A
P
tot
Total dissipation at T
C
= 25°C 70 25 W
Derating factor 0.47 0.17 W/°C
dv/dt
(3)
3. I
SD
≤ 36A, di/dt ≤ 400A/µs, V
DD
≤ V
(BR)DSS
, Tj ≤ T
JMAX
Peak diode recovery voltage slope 20 V/ns
E
AS
(4)
4. Starting T
j
= 25 °C, I
D
= 18A, V
DD
= 45V
Single pulse avalanche energy 200 mJ
V
ISO
Insulation withstand voltage
three leads to external heat
(t = 1s; Tc = 25°C)
-- 2500 V
T
stg
Storage temperature
-55 to 175 °C
T
j
Max. operating junction temperature
Table 2. Thermal data
TO-220 TO-220FP
Rthj-case Thermal resistance junction-case max 2.14 6 °C/W
Rthj-amb Thermal resistance junction-ambient max 62.5 °C/W
T
J
Maximum lead temperature for soldering
purpose
(1)
1. 1.6 mm from case, for 10 sec.
300 °C