SPECIFICATION
DR-15-5 DR-15-12 DR-15-15 DR-15-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD Note.5
OVER VOLTAGE
5V 12V 15V 24V
2.4A 1.25A 1A 0.63A
0 ~ 2.4A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.63A
12W 15W 15W 15.2W
80mVp-p 120mVp-p 120mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
±2.0% ±1.0% ±1.0% ±1.0%
10.8 ~ 13.2V4.75 ~ 5.5V
±1.0% ±1.0% ±1.0% ±1.0%
±1.0% ±1.0% ±1.0% ±1.0%
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load
70ms/230VAC 16ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
77% 84% 83.5% 85%
0.88A/115VAC 0.48A/230VAC
COLD START 35A/115VAC 65A/230VAC
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V
Protection type : Shut off o/p voltage, clamping by zener diode
13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
-20 ~ +60℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
1172.3K hrs min. MIL-HDBK-217F (25℃)
℃
File Name:DR-15-SPEC 2011-06-17
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
15W Single Output Industrial DIN Rail Power Supply
DR-15 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
‧
‧
‧
‧
‧Ⅱ
‧
‧
‧
‧
■
25*93*56mm (W*H*D)
0.1Kg; 140pcs/15Kg/0.92CUFT
..
EMC IMMUNITY
EMC EMISSION