412-K14-N2-10A

High Performance Thermal Circuit Breaker 412-...
www.e-t-a.de
1646 1
1
Description
Typical applications
Ordering information
Approvals
Technical data
Single pole high performance thermal circuit breaker with tease-free,
trip-free, snap action mechanism and push/pull on/off manual actuation
(M-type TO CBE to EN 60934). An indicator band on the push button
clearly shows the tripped/off position. Threadneck panel mounted and
available in tracked vehicle, aircraft and general purpose versions.
Extra low voltage wiring systems on all types of vehicles for land, sea
and air; defence equipment; battery powered machines.
412-...
Standard current ratings and typical voltage drop values
Type No.
412 threadneck panel mounting
Terminal design
K14 screw terminals M4 (to aircraft specs.)
K54 screw terminals M4 sealed housing (to vehicle specs.)
Version
FN2 vehicle application, nickel-plated
LN2 aircraft application, black finish
N2 general application, nickel-plated
Current ratings
6...25 A (-FN2)
7.5...35 A (-LN2/N2)
412 - K14 - LN2 - 10 A ordering example
Voltage rating DC 28 V
AC 115 V (400 Hz) upon request
Current rating range 6...25 A (-FN2)
7.5...35 A (-LN2/-N2),
lower current ratings to special order
Typical life 4,000 operations at 2 x I
N
Ambient temperature -55...+75 °C (-67...+167 °F)
Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664A) withstand voltage degree
1.5 kV 3
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 1,500 V
Insulation resistance > 100 MΩ (DC 500 V)
Interrupting capacity I
cn
6,000 A
Interrupting capacity
(UL 1077) 6,000 A
Degree of protection operating area IP40
(IEC 60529/DIN 40050) terminal area IP00
Vibration 10 g (56-500 Hz), ± 0.76 mm (10-55 Hz)
to VG 95210, sheet 19,
MIL-STD-202, meth. 204,
IEC 60068-2-6, test Fc
Shock 25 g (11 ms)
to VG 95210, sheet 28,
MIL-STD-202, meth. 213,
IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to VG 95210, sheet 2,
MIL-STD-202, meth. 101,
IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to VG 95210, sheet 7,
MIL-STD-202, meth. 106,
IEC 60068-2-3, test Ca
Mass approx. 40 g
Current
rating (A)
Voltage
drop (mV)
Current
rating (A)
Voltage
drop (mV)
-LN/N -FN -LN/N -FN
6 - ≤ 300 15 ≤ 200 ≤ 200
7.5 ≤ 300 ≤ 250 20 ≤ 200 ≤ 200
8 ≤ 250 ≤ 200 25 ≤ 200 ≤ 200
10 ≤ 200 ≤ 200 30 ≤ 200 -
12 ≤ 200 ≤ 200 35 ≤ 200 -
13 ≤ 200 ≤ 200
Preferred types Standard current ratings (A)
6 7.5 8 10 15 20 25 30 35
412-K54-FN2-
x x x x x x x
412-K14-LN2-
x x x x x x x x
412-K54-LN2-
x x x x x x x
Preferred types
Authority Standard Rated voltage Current ratings
UL UL 1077 DC 28 V 0.1 A...35 A
CSA C22.2 No
235
DC 28 V 0.1 A…35 A
High Performance Thermal Circuit Breaker 412-...
www.e-t-a.de
1646
2
1
Trip time in seconds
… times rated current
+75 °C
+167 °F
+23 °C
+73.4 °F
-55 °C
-67 °F
0.001
12468
10
20 40
10000
1000
100
10
1
0.1
0.01
6080100
Trip time in seconds
… times rated current
12468
10 20 40
10000
1000
100
10
1
0.1
0.01
0.001
6080100
+75 °C
+167 °F
+23 °C
+73.4 °F
-55 °C
-67 °F
Dimensions
Typical time/current characteristics
Internal connection diagram
ON
terminal version
< 6 A
max. 098
max. 2.5
9.5
±0.2
thickness 1.5 - 3 mm
.059 - .118 in.
min. ø3.2
min .126
current rating in A
5
9.5
location pin
2.7
SW14
29
14.5
.571
.374
.551
1.14
.106
terminal version
<7.5 A
current rating in A
mounting holes
screw ISO1580-M4x6
washer DIN 137-B4
tightening torque max. 1.2 Nm
max. 2.5
35°
35°
M12x1
black
white
lock
washer
4
10.6
ø10.6
6.5
46
58
52
OFF
12.2
6
1.5
20
tightening torque max. 4 Nm
5
20
9.5
location pin
2.7
SW14
29
14.5
min. ø3.2
ø12.5
+0.2
9.5
±0.2
10.6
35°
35°
terminal version >7.5 A
thickness 1.5 - 3 mm
.059 - .118 in.
.374
±.008
min .126
.492
+.008
.571
.374
.551
1.14
.106
.787
max. .098
.417
ø12.5
+0.2
.492
+.008
mounting holes
.374
±.008
screw ISO1580-M4x6
washer DIN 137-B4
tightening torque max. 1.2 Nm
terminal version > 6 A
.787
.417
.157
.256
1.81
2.28
2.05
.417
.059
.236
.480
412-K54-FN2/N2
412-K14/K54-FN2/N2
412-K14-LN2
412-K14/K54-LN2
2
line 1
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
412-...-FN2 6...25 A
412-..LN2/-N2 7.5...35 A
High Performance Thermal Circuit Breaker 412-...
www.e-t-a.de
1646 3
1
High Performance Thermal Circuit Breaker 412-...
Accessories (approved to VG 95345, part 23)
Splash cover black /hex nut assembly with O ring (IP54)
X 200 802 01 nickel plated nut M12x1
X 200 802 02 matt black finish nut M12x1
Splash cover /hex nut assembly with O ring (IP66 and IP67)
X 200 801 08 nickel plated nut M12x1, transparent cover
X 200 801 03 matt black finish nut M12x1, black cover
X 200 801 12 with blackened nut and transparent cover
M12x1
A
ctuator extension (black)
to be fitted on the push button
X 200 803 01
M12x1
ø20
17
ø.787
.669
Accessories
Identification collar to be snapped on the push button
Y
307 004 01 black
Y
307 004 02 white
Y
307 004 03 red
Y
307 004 04 green
Y
307 004 05 blue
Lock out ring to block the push button in OFF position
Y
307 005 01 red
Y
307 005 02 black
6.4
ø6.85
ø12.35
ø14
.270
.551
.486
.252
0.65
.026
0.8
.031
7.7
ø10.9
ø14.6
.575
.303
.429
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.

412-K14-N2-10A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: