Reliability data
Test Standard Test conditions R
25
/R
25
Electrical endurance,
cycling
IEC 60738-1 Room temperature, I
Smax
; V
max
Number of cycles: 10
< 20%
Electrical endurance,
constant
IEC 60738-1 Storage at V
max
/T
op,max
(V
max
)
Test duration: 1000 h
< 25%
Damp heat IEC 60738-1 Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
< 10%
Rapid change
of temperature
IEC 60738-1 T
1
= T
op,min
(0 V), T
2
= T
op,max
(0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
< 10%
Vibration IEC 60738-1 Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, test Fc
< 5%
Shock IEC 60738-1 Acceleration: 390 m/s
2
Pulse duration: 6 ms; 6 × 4000 pulses
< 5%
Climatic sequence IEC 60738-1 Dry heat: T = T
op,max
(0 V)
Test duration: 16 h
Damp heat first cycle
Cold: T = T
op,min
(0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
< 10%
Overcurrent protection for telecom
Telecom pair protector (TPP), SMD
Page 7 of 13Please read Cautions and warnings and
Important notes at the end of this document.
ITU performance overview and fault conditions
Test
no.
ITU K20 ITU K21 ITU K45
Basic
test level
Enhanced
test level
Basic
test level
Enhanced
test level
Basic
test level
Enhanced
test level
Power induction
1 A A A A A A
2 B C B C B C
Power contact 3 D E D E D E
Lightning surge
4 F G G G G G
5 H H H I H H
Power induction
A
600 V AC, R = 600 , t = 0.2 s, criteria A
B
600 V AC, R = 600 , t = 1.0 s, with GDT, criteria A
C
1500 V AC, R = 200 , t = 2.0 s, with GDT, criteria A
Power contact
D
230 V AC, t = 15 min, R = 10 ... 1000 , criteria B
E
230 V AC, t = 15 min, R = 10, 20, 40, 80, 1000 , criteria B,
R = 160, 300, 600 , criteria A
Lightning surge
F
V
c(max)
= 1.0 kV, R = 25 , t = 10/700 µs, without GDT, criteria A
G
V
c(max)
= 1.5 kV, R = 25 , t = 10/700 µs, without GDT, criteria A
H
V
c(max)
= 4.0 kV, R = 25 , t = 10/700 µs, with GDT, criteria A
I
V
c(max)
= 6.0 kV, R = 25 , t = 10/700 µs, with GDT, criteria A
Criteria A: no damage, function must be fulfilled.
Criteria B: no fire hazard.
Electrical requirements according to GR-1089 standard for AC power contact
AC voltage: 120 V, 50 Hz, short circuit current 25 A, time 15 min, criteria A.
Overcurrent protection for telecom
Telecom pair protector (TPP), SMD
Page 8 of 13Please read Cautions and warnings and
Important notes at the end of this document.
Cautions and warnings
General
EPCOS thermistors are designed for specific applications and should not be used for purposes
not identified in our specifications, application notes and data books unless otherwise agreed
with EPCOS during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The ther-
mistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative hu-
midity 75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term opera-
tion (examples given under operation precautions).
Use thermistor within the following period after delivery:
Through-hole devices (housed and leaded PTCs): 24 months
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months
Telecom pair and quattro protectors (TPP, TQP): 24 months
Leadless PTC thermistors for pressure contacting: 12 months
Leadless PTC thermistors for soldering: 6 months
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months
SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Overcurrent protection for telecom
Telecom pair protector (TPP), SMD
Page 9 of 13Please read Cautions and warnings and
Important notes at the end of this document.

B59805T1080A62

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
THERMISTOR PTC 4.75 OHM 15% 4SMD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: