Page 8 ams Datasheet
Document Feedback [v1-00] 2015-Apr-01
HLS-440P − Electrical Inter face
Byte 0 H
2
Concentration
Figure 8:
Byte 0 Bit Order
This byte shows the H
2
concentration in a resolution of 0.05.
x = Concentration in % Hydrogen
Byte value = (x % H
2
)* 200/ (10 % H
2
)
x % = byte value *(10 % H
2
)/200
Range: 0 - 200 (Hexadecimal 0 - C8)
No value: 255 (Hexadecimal FF)
Values: 0 - 10 % H
2
Resolution: 0.05 = (10 % H
2
) / 200
The No value is sent if there is no valid H
2
concentration
(accompanied by Not_ready bit in status byte (Byte 1))
Byte 1 Status
Figure 9:
Byte 1 Status Bit Assignment
This byte shows the status of the module.
Bit 0: If the not_ready bit is set, the module is not up or not
working.
Value: 0 or 1
Bit 1 + 2: The error category
Value: 0 - 3
The figure below describes the error category definition
Bit
MSB
7
6 5 4 3 2 1
LSB
0
Byte 0 XXXXXXXX
Bit
MSB
7
6 5 4 3 2 1
LSB
0
Byte 1 Bit 7
Bit 6
Neg_
drift3
Bit 5
Neg_
drift2
Bit 4
Neg_
drift1
Bit 3
EMC_
Corr
Bit 2 Err_
Category
Bit 1 Err_
Category
Not_ready
(EQ1)
(EQ2)
ams Datasheet Page 9
[v1-00] 2015-Apr-01 Document Feedback
HLS-440P − Electrical Interface
Figure 10:
Definition of Error Category
Bit 3: EMC_Corr...EMC correction active
Value: 0 or 1
Bit 4: Negative drift info. If this bit is set, the prediction has gone
below the first of three warning levels.
Bit 5: Negative drift warning. If this bit is set, the prediction has
gone below the second warning level.
Bit 6: Negative drift alarm. If this bit is set, the prediction has
gone below the third warning level.
Bit 7 is not used.
Byte 4 Software Version Y.Z
Figure 11:
Byte 4 Software Version Numbering Code
This byte shows the firmware version.
View: Y.Z
Range: 0 - 255 (Hexadecimal 0 - FF)
Value: 0.0 - 15.15 (Hexadecimal 0.0 - F.F)
Code Name Description
0 No error Sensor OK
1 Performance error General function still given; Warm start-up indication (<5 s)
2 Slight functional error
General function still given but high likelihood for
upcoming severe error (sensor should be replaced)
3 Severe functional error
Severe error, general function NOT given anymore, sensor
not longer trustable (=signal not available)
Bit
MSB
7
6 5 4 3 2 1
LSB
0
Byte 4 YYYYXXXX