DC and AC parameters STM1001
12/18 Doc ID 10373 Rev 6
5 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 3: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 3. Operating and AC measurement conditions
Figure 11. AC testing input/output waveforms
Parameter STM1001 Unit
V
CC
supply voltage 1.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Input rise and fall times ≤ 5ns
Input pulse voltages 0.2 to 0.8 V
CC
V
Input and output timing ref. voltages 0.3 to 0.7 V
CC
V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC