Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-200 DC-DC Converters 50 to 200 Watts Rev. 3.3 Page 1 of 5
Set your site on VICOR at vicorpower.com
Features
RoHS compliant (VE-200)
Up to 50 W/in
3
cULus, cTÜVus
Up to 90% efficiency
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7mm)
Remote sense and current limit
OVP, thermal shutdown
Logic disable
Wide range output adjust
Compatible power booster modules
ZCS power architecture
Low noise FM control
CE Marked
Isolated output
Data Sheet
VI-200, VE-200
DC-DC Converters
50 to 200 Watts
Product Highlights
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of
“zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2 MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable of
supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
Low Line
75%
Vin
2 3.3 5 5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95
Voltage
Max Power
Transient
[b]
Designators
ZY0XWVTRM1P 2N3LJK4HFDB
Nom. (Range)
12 (10-20) n/a 22 0 XXXXXXXXXXXXXXXXXXXXXX
24 (10-36) n/a n/a V --XYYYYYXXXXXXXXXXX--------
24 (21-32) 18 36 1 UUUUUUVVUUUUUUUUUUUUUU
24 (18-36) n/a n/a W VVVVVVWWVVVVVVVVVVVVVV
36 (21-56) 18 60 2 WV WWWWWWWWWWWWWWWWW -- -- --
48 (42-60) 36 72 3 UUUUUUUUUUUUUUUUUUUUUU
48 (36-76) n/a n/a N VUUUUUUUUUUUUUUUUUUUUU
72 (55-100) 45 110 4 UUUUUUVVUUUUUUUUUUUUUU
110 (66-160) n/a n/a T VVVVVVWWVVVVVVVVVVVV----
150 (100-200) 85
[c]
215 5 UUVVVVVVUUUUUUUUUUUUUU
150 (100-375) n/a n/a 7 WW Y Y Y Y WWWWWWWWWWWWW-- -- --
300 (200-400) 170
[d]
425 6 UUUUU UVVUUUUUUUUUUUUUU
Part Numbering
Maximum Power Available for VI-2xx-xx
[a]
[a]
For additional output power, “booster” modules are available. (VI-Bxx-xx)
[c]
15 Vout, 200 W models are limited to 90 Vdc
[b]
Transient voltage for 1 second.
[d]
15 Vout, 200 W models are limited to 185 Vdc
Note: For additional
packaging options,
please see page 4.
Input Output
Vout Designators
VI261CW
Family Series Input Output Grade Power
VI = Non-RoHS 2 = 200 0 = 12 V N =48V Z =2V M =10V K =40V E = –10 to 85°C ≥ 5 V < 5 V
VE = RoHS B = Booster V = 24 V 4 =72V Y =3.3V 1 =12V 4 =48V C = –25 to 85°C U = 200 W U = 40 A
1 =24V T = 110 V 0 =5V P = 13.8 V H =52V I = 40 to 85°C V = 150 W V = 30 A
W =24V 5 = 150 V X =5.2V 2 =15V F =72V M = –55 to 85°C W = 100 W W = 20 A
2 =36V 6 = 300 V W =5.5V N = 18.5 V D =85V X = 75 W X = 15 A
3 =48V 7 = 150/300 V V =5.8V 3 =24V B =95V Y = 50 W Y = 10 A
T =6.5V
L =28V
R =7.5V J =36V
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-200 DC-DC Converters 50 to 200 Watts Rev. 3.3 Page 2 of 5
Set your site on VICOR at vicorpower.com
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Inrush charge 120 x 10
-6
120 x 10
-6
200 x 10
-6
Coulombs Nominal line
Input reflected
10% 10% I
IN Nominal line, full load
ripple current – pp
Input ripple rejection dB 120 Hz, nominal line
dB 2400 Hz, nominal line
No load power dissipation 1.35 2 1.35 2 Watts
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Gate out impedance 50 50 Ohms
Gate in impedance 1000 1000 Ohms
Gate in open circuit voltage 6 6 Volts Use open collector
Gate in low threshold 0.65 0.65 Volts
Gate in low current 6 6 mA
Power sharing accuracy 0.95 1.05 0.95 1.05
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Setpoint accuracy 1% 2% 0.5% 1% VNOM
Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load
Load/line regulation 1% 0.2% 0.5% VNOM LL to HL, No Load to 10%
Output temperature drift 0.02 0.01 0.02 % / °C Over rated temp.
Long term drift 0.02 0.02 %/1K hours
Output ripple – pp:
2 V, 3.3 V 150 60 100 mV 20 MHz bandwidth
5 V 5% 2% 3% VNOM 20 MHz bandwidth
10 – 95 V 3% 0.75% 1.5% VNOM 20 MHz bandwidth
Tr i m r ange
[a]
50% 110% 50% 110% VNOM
To t al remote
0.5 0.5 Volts 0.25 V max. neg. leg
sense compensation
OVP set point 125%
[b]
115% 125%
[b]
135% VNOM Recycle power
Current limit 105% 135% 105% 125% Ifull load Automatic restart
Short circuit current
[c]
20% 140% 20% 130% Ifull load Automatic restart
CONVERTER SPECIFICATIONS
(typical at T
BP
= 25°C, nominal line and 75% load, unless otherwise specified)
25+ 20 Log
(
Vin
)
Vout
30+ 20 Log
(
Vin
)
Vout
20+ 20 Log
(
Vin
)
Vout
[a]
10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
3.3 V output trim range 2.20 to 3.63 V, 95 V output –50 + 0% trim range.
[b]
131% nominal for booster modules.
[c]
Output voltages of 3.3 V or 5 V incorporate foldback current limiting; For output voltages from 5.2 V to 7.5 V consult factory; All other outputs provide constant current limiting.
INPUT SPECIFICATIONS
OUTPUT CHARACTERISTICS
CONTROL PIN SPECIFICATIONS
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 VI-200 DC-DC Converters 50 to 200 Watts Rev. 3.3 Page 3 of 5
Set your site on VICOR at vicorpower.com
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Efficiency 78 – 88% 80 – 90%
Baseplate to sink
0.07 0.07 °C/Watt With Vicor P/N 20266
thermal impedance
Thermal shutdown
[d]
90 95 105 90 95 105 °C
Cool and recycle power
(Drivers only) to restart
CONVERTER SPECIFICATIONS (cont.)
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Input to output 3,000 3,000 VRMS Baseplate earthed
Output to baseplate 500 500 VRMS
Input to baseplate 1,500 1,500 VRMS
VI-200 E-, C-Grade VI-200 I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test Conditions
Weight
5.7 6.3 6.9 6.6 7.3 8.1 Ounces
(160.2) (178) (195.8) (187.2) (208) (228.8) (Grams)
DIELECTRIC WITHSTAND CHARACTERISTICS
THERMAL CHARACTERISTICS
MECHANICAL SPECIFICATIONS
Parameter Storage Operating Units Notes
E -20 to +100 -10 to + 85 °C
Overtemperature shutdown
C -40 to +100 -25 to + 85 °C
95°C typical (recycle power
I -55 to +100 -40 to + 85 °C
to restart)
M -65 to +100 -55 to + 85 °C
PRODUCT GRADE TEMPERATURES
[d]
No overtemp protection in booster modules.