MAX13050/MAX13052/MAX13053/MAX13054
Industry-Standard High-Speed CAN
Transceivers with ±80V Fault Protection
4
Maxim Integrated
DC ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +5V ±5%, V
CC
2 = +3V to +3.6V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V
CC
= +5V, V
CC
2 = +3.3V,
R
L
= 60Ω, and T
A
= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Voltage for Standby V
IH
_
RS
0.75 x
V
CC
V
Slope-Control Mode Voltage V
SLOPE
-200µA < I
RS
< 10µA
0.4 x
V
CC
0.6 x
V
CC
V
High-Speed Mode Current I
IL_RS
V
RS
= 0 -500 µA
ESD Protection
IEC 61000-4-2 Contact Discharge Method
per IBEE test facility (Note 3)
±8 kV
TIMING CHARACTERISTICS
(V
CC
= +5V ±5%, V
CC
2 = +3V to +3.6V, R
L
= 60Ω, C
L
= 100pF, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at
V
CC
= +5V, V
CC
2 = +3.3V, and T
A
= +25°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Delay TXD to Bus Active t
ONTXD
Figure 1 (Note 4) 66 110 ns
MAX13050/MAX13052/
MAX13053
61 95
Delay TXD to Bus Inactive t
OFFTXD
Figure 1
(Note 4)
MAX13054 70 110
ns
Delay Bus to Receiver Active t
ONRXD
Figure 1 (Note 4) 54 115 ns
Delay Bus to Receiver Inactive t
OFFRXD
Figure 1 (Note 4) 46 160 ns
Delay TXD to RXD Active
(Dominant Loop Delay)
t
ONLOOP
Figure 1 (Note 4) 121 255 ns
Delay TXD to RXD Inactive
(Recessive Loop Delay)
t
OFFLOOP
Figure 4 (Note 4) 108 255 ns
R
RS
= 24kΩ
(500kbps)
280 450 ns
R
RS
= 100kΩ
(125kbps)
0.82 1.6
Delay TXD to RXD Active
(Dominant Loop Delay) Slew-Rate
Controlled
t
ONLOOP-S
MAX13052
R
RS
= 180kΩ
(62.5kbps)
1.37 5
µs
R
RS
= 24kΩ
(500kbps)
386 600 ns
R
RS
= 100kΩ
(125kbps)
0.74 1.6
Delay TXD to RXD Inactive (Loop
Delay) Slew-Rate Controlled
t
OFFLOOP-S
MAX13052
R
RS
= 180kΩ
(62.5kbps)
0.97 5
µs
R
RS
= 24kΩ
(500kbps)
10
R
RS
= 100kΩ
(125kbps)
2.7
Differential Output Slew Rate |SR| MAX13052
R
RS
= 180kΩ
(62.5kbps)
1.6
V/µs