19-3598; Rev 1; 2/13
MAX13050/MAX13052/
MAX13053/MAX13054
Industry-Standard High-Speed CAN
Transceivers with ±80V Fault Protection
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
General Description
The MAX13050/MAX13052/MAX13053/MAX13054 are pin-
for-pin compatible, industry-standard, high-speed, control
area network (CAN) transceivers with extended ±80V fault
protection. These products are ideal industrial network
applications where overvoltage protection is required.
These CAN transceivers provide a link between the CAN
protocol controller and the physical wires of the bus lines in
a CAN. These devices can be used for DeviceNet
®
applications, requiring data rates up to 1Mbps.
The CAN transceivers have an input common-mode
range greater than ±12V, exceeding the ISO11898
specification of -2V to +7V, and feature ±8kV ESD pro-
tection, making these devices ideal for harsh industrial
environments.
The CAN transceivers provide a dominant timeout func-
tion that prevents erroneous CAN controllers from clamp-
ing the bus to a dominant level if the TXD input is held low
for greater than 1ms. The MAX13050/MAX13052 provide
a SPLIT pin used to stabilize the recessive common-
mode voltage. The MAX13052 also has a slope-control
mode that can be used to program the slew rate of the
transmitter for data rates of up to 500kbps. The
MAX13053 features a silent mode that disables the trans-
mitter. The MAX13053 also has a reference output that
can be used to bias the input of older CAN controllers
that have a differential comparator. The MAX13054 has a
separate dedicated logic input, V
CC2
, allowing interfacing
with a +3.3V microcontroller.
The MAX13050/MAX13052/MAX13053/MAX13054 are
available in an 8-pin SO package and are specified to
operate in the -40°C to +85°C and the -40°C to +125°C
temperature ranges.
Features
o Fully Compatible with the ISO11898 Standard
o ±8kV ESD IEC 61000-4-2 Contact Discharge per
IBEE Test Facility
o ±80V Fault Protection
o +3.3V Logic Compatible (MAX13054)
o High-Speed Operation of Up to 1Mbps
o Slope-Control Mode (MAX13052)
o Greater than ±12V Common-Mode Range
o Low-Current Standby Mode
o Silent Mode (MAX13053)
o Thermal Shutdown
o Short-Circuit Protection
o Transmit (TXD) Data Dominant Timeout
o Current Limiting
o SPLIT Pin (MAX13050/MAX13052)
Ordering Information
PART TEMP RANGE PIN-PACKAGE
MAX13050ESA+ -40°C to +85°C 8 SO
MAX13050ASA+ -40°C to +125°C 8 SO
MAX13052ESA+ -40°C to +85°C 8 SO
MAX13052ASA+ -40°C to +125°C 8 SO
MAX13053ESA+ -40°C to +85°C 8 SO
MAX13053ASA+ -40°C to +125°C 8 SO
MAX13054ESA+ -40°C to +85°C 8 SO
MAX13054ASA+ -40°C to +125°C 8 SO
Selector Guide
PART SPLIT
SLOPE
CONTROL
STANDBY
MODE
SILENT
MODE
3.3V
SUPPLY
REF
PIN-FOR-PIN
REPLACEMENT
MAX13050 Yes Yes TJA1040
MAX13052 Yes Yes Yes PCA82C250/51
MAX13053 Yes Yes
TJA1050,
AMIS-30660
MAX13054 Yes Yes
TLE6250v33,
CF163
Pin Configurations, Functional Diagrams, and Typical
Operating Circuits appear at end of data sheet.
DeviceNet Nodes
Medium- and Heavy-Duty
Truck Systems
Industrial
Applications
DeviceNet is a registered trademark of the Open DeviceNet
Vendor Association.
+
Denotes a lead(Pb)-free/RoHS-compliant package.
MAX13050/MAX13052/MAX13053/MAX13054
Industry-Standard High-Speed CAN
Transceivers with ±80V Fault Protection
2
Maxim Integrated
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
, V
CC
2 ...............................................................-0.3V to +6V
RS ...............................................................-0.3V to (V
CC
+ 0.3V)
TXD, STBY, S, REF, RXD .........................................-0.3V to +6V
CANH, CANL, SPLIT ..........................................................± 80V
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C) .................470mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature......................................................+150°C
Storage Temperature Range .................................-65°C +150°C
Lead Temperature (soldering, 10s) ................................+300°C
Soldering Temperature (reflow) ......................................+260°C
DC ELECTRICAL CHARACTERISTICS
(V
CC
= +5V ±5%, V
CC
2 = +3V to +3.6V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V
CC
= +5V, V
CC
2 = +3.3V,
R
L
= 60Ω, and T
A
= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Dominant, R
L
= 60 72
MAX13050/MAX13052/
MAX13053
12.5
V
CC
Supply Current I
CC
Recessive
MAX13054 10
mA
V
CC
2 Supply Current I
CC2
MAX13054, TXD = V
CC
2 or unconnected 15 µA
MAX13052 25
Standby Current I
STANDBY
MAX13050/MAX13054 11
µA
Silent Mode I
SILENT
MAX13053 12.5 mA
Thermal-Shutdown Threshold T
SH
+165 °C
Thermal-Shutdown Hysteresis 13 °C
INPUT LEVELS (TXD, STBY, S)
2
High-Level Input Voltage V
IH
TXD, STBY (MAX13054)
0.7 x
V
CC
2
V
0.8
Low-Level Input Voltage V
IL
TXD, STBY (MAX13054)
0.3 x
V
CC
2
V
V
TXD
= V
CC
, V
TXD
= V
CC
2 (MAX13054) -5 +5
High-Level Input Current I
IH
V
STBY
= V
CC
, V
S
= V
CC
(MAX13053) -5 +5
µA
V
TXD
= GND -300 -100
Low-Level Input Current I
IL
V
STBY
= GND, V
S
= GND (MAX13053) -10 -1
µA
Input Capacitance C
IN
10 pF
CANH, CANL TRANSMITTER
Normal mode, V
TXD
= V
CC
, no load 2 3 V
Recessive Bus Voltage
V
CANH
,
V
CANL Standby mode, no load -100 +100 mV
V
CANH
, V
CANL
= ±76V ±3
Recessive Output Current
I
CANH
,
I
CANL
-32V V
CANH
, V
CANL
+32V -2.5 +2.5
mA
CANH Output Voltage V
CANH
V
TXD
= 0, dominant 3.0 4.25 V
CANL Output Voltage V
CANL
V
TXD
= 0, dominant 0.50 1.75 V
Matching Between CANH and
CANL Output Voltage
DOM
V
TXD
= 0, dominant, T
A
= +25°C,
(V
CANH
+ V
CANL
) - V
CC
-100 +150 mV
MAX13050/MAX13052/MAX13053/MAX13054
Industry-Standard High-Speed CAN
Transceivers with ±80V Fault Protection
3
Maxim Integrated
DC ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +5V ±5%, V
CC
2 = +3V to +3.6V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V
CC
= +5V, V
CC
2 = +3.3V,
R
L
= 60Ω, and T
A
= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Dominant, V
TXD
= 0, 45 R
L
60 1.5 3.0 V
Differential Output
(V
CANH
- V
CANL
)
V
DIFF
Recessive, V
TXD
= V
CC
, no
load -50 +50 mV
CANH Short-Circuit Current I
CANHSC
V
CANH
= 0, V
TXD
= 0 -100 -70 -45 mA
V
CANL
= 5V, V
TXD
= 0 406090
V
CANL
= 40V, V
TXD
= 0 (Note 2) 40 60 90CANL Short-Circuit Current I
CANLSC
V
CANL
= 76V, V
TXD
= 0 63
mA
RXD OUTPUT LEVELS
I = -100µA
0.8 x
V
CC
V
CC
RXD High-Output-Voltage Level V
OH
I = -100µA (MAX13054)
0.8 x
V
CC
2
V
CC
2
V
RXD Low-Output-Voltage Level V
OL
I = 5mA 0.4 V
COMMON-MODE STABILIZATION (SPLIT) and REF
Output Voltage V
SPLIT
Normal mode,
-500µA I
SPLIT
500µA
0.3 x
V
CC
0.7 x
V
CC
V
Standby mode, -40V V
SPLIT
+40V 20
Leakage Current I
LEAK
Standby mode, -76V V
SPLIT
+76V 50
µA
REF Output Voltage V
REF
-50µA I
REF
+50µA (MAX13053)
0.45 x
V
CC
0.55 x
V
CC
V
DC BUS RECEIVER (V
TXD
= V
CC
, CANH and CANL externally driven)
-12V V
CM
+12V 0.5 0.7 0.9
Differential Input Voltage V
DIFF
MAX13050/MAX13052/MAX13054
-12V V
CM
+12V (standby mode)
0.50 1.15
V
Differential Input Hysteresis V
D IF F
(
H Y S T
)
Normal mode, -12V V
CM
+12V 70 mV
Common-Mode Input Resistance R
ICM
Normal or standby mode,
V
CANH
= V
CANL
= ±12V
15 35 k
Matching Between CANH and
CANL Common-Mode Input
Resistance
R
IC_MATCH
V
CANH
= V
CANL
-3 +3 %
Differential Input Resistance R
DIFF
Normal or standby mode,
V
CANH
- V
CANL
= 1V
25 75 k
Common-Mode Input
Capacitance
C
IM
V
TXD
= V
CC
20 pF
Differential Input Capacitance V
TXD
= V
CC
10 pF
Input Leakage Current I
LI
V
CC
= 0, V
CANH
= V
CANL
= 5V -5 +5 µA
SLOPE CONTROL RS (MAX13052)
Input Voltage for High Speed V
IL_RS
0.3 x
V
CC
V

MAX13053ESA+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
CAN Interface IC CAN Transceiver w/80V Fault Protect
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union