2036-40-C6F

*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
2036 Series - Miniature 3-Pole Gas Discharge Tube
Features
Balanced Mini-TRIGARD™
5 mm diameter, 7.5 mm long
UL Recognized
RoHS compliant* versions available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
Impulse Transverse Delay......................................100 V/µs.......................................................................< 75 ns
Insulation Resistance.............................................100 V (50 V for Model 2036–07 & 2036-09).................> 10
10
Glow Voltage..........................................................10 mA...........................................................................~ 70 V
Arc Voltage.............................................................1 A................................................................................~ 10 V
Glow-Arc Transition Current ........................................................................................................................< 0.5 A
Capacitance...........................................................1 MHz...........................................................................< 2 pF
DC Holdover Voltage
1
...........................................135 V, (52 V for Model 2036-07 & 2036-09,.................< 150 ms
80 V for Model 2036-15)
Impulse Discharge Current ....................................20000 A, 8/20 µs
2
......................................................... 1 operation minimum
10000 A, 8/20 µs..........................................................> 10 operations
200 A, 10/1000 µs .......................................................> 300 operations
200 A, 10/700 µs .........................................................> 500 operations
Alternating Discharge Current................................20 Arms, 1 s
2
................................................................ 1 operation minimum
10 Arms, 1 s.................................................................> 10 operations
Operating Temperature................................................................................................................................ -55 to +85 °C
Optional Switch-Grade Failsafe device available.
Notes:
•UL recognized component, UL File E153537.
Model number marking on tube: xxx V.
The rated discharge current for Mini-TRIGARD
Gas Discharge Tubes is the total current equally divided between each line to ground.
Sparkover limits after life ±25 %, IR >10
8
(-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
1
Network applied.
2
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31
Characteristic
Model No.
2036-07 2036-09 2036-15 2036-20 2036-23 2036-25
DC Sparkover ±20 % @ 100 V/s 75 V 90 V 150 V 200 V 230 V 250 V
Impulse Sparkover
100 V/µs
1000 V/µs
250 V
525 V
250 V
550 V
350 V
500 V
425 V
575 V
450 V
600 V
475 V
625 V
Characteristic
Model No.
2036-30 2036-35 2036-40 2036-42 2036-47 2036-60
DC Sparkover ±20 % @ 100 V/s 300 V 350 V 400 V 420 V 470 V 600 V
Impulse Sparkover
100 V/µs
1000 V/µs
500 V
650 V
600 V
750 V
650 V
825 V
675 V
850 V
750 V
950 V
850 V
1100 V
*RoHS COMPLIANT
VERSIONS
AVAILABLE
*Center Electrode Lead: See Center Lead C-Configuration detail.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
2036 Series - Miniature 3-Pole Gas Discharge Tube
Product Dimensions
2036-XX-A
5.1
(.202)
0.7 - 1.0
(.028 - .040)
DIA.
DIA.
7.4 - 7.7
(.290 - .303)
2036-XX-B2 — 0.8 mm (0.032 in.) dia. lead wire
2036-XX-C2 — 1.0 mm (0.040 in.) dia. lead wire*
2036-XX-B3 — 0.8 mm (0.032 in.) dia. lead wire
2036-XX-C3 — 1.0 mm (0.040 in.) dia. lead wire*
2036-XX-B9 — 0.8 mm (0.032 in.) dia. lead wire
2036-XX-C9 — 1.0 mm (0.040 in.) dia. lead wire*
4.0
(.157)
4.4
(.173)
4.4
(.173)
4.0
(.157)
3.8
(.150)
3.8
(.150)
4.0
(.157)
9.5
(.374)
19.0
(.748)
4.0
(.157)
25.0
(0.99)
LONG MIN.
0.8
(.032)
4.0
(.157)
25.0
(0.99)
LONG MIN.
2036-XX-B8 — 0.8 mm (0.032 in.) dia. lead wire
2036-XX-C8 — 1.0 mm (0.040 in.) dia. lead wire*
FAILSAFE CONFIGURATION
2036-XX-B2F SHOWN
CENTER ELECTRODE LEAD: C-CONFIGURATION
2036-XX-B — 0.8 mm (0.032 in.) dia. lead wire
2036-XX-C — 1.0 mm (0.040 in.) dia. lead wire*
Optional
Configuration
4.0
(.157)
0.8
(.032)
6.2
(.244)
5.3
(.208)
4.0
(.157)
1.0
(.040)
DIMENSIONS =
MILLIMETERS
(INCHES)
2036 Series - Miniature 3-Pole Gas Discharge Tube
Switch-Grade Failsafe Device Shorting Curve 2036-XX-XF
1.0
10.0
5.0
0.5
Current (A) (ELTGS)
0.1
0.1
110
ELTGS = Each Line to Ground Simultaneously
NOTE: When using a GDT failsafe device, it is imperative that all components
associated and connected to the GDT with failsafe be tested in their respective
completely integrated environment (finished product) to assure proper operation.
Seconds
100
REV 05/06
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Packaging Specifications
Model 2036-xx-nn ships standard bulk pack, 100 pcs./tray.
How To Order
2036 - xx - x - nn - F LF
Model Number
Designator
Voltage (Divided by 10)
07 = 75 V 30 = 300 V
09 = 90 V 35 = 350 V
15 = 150 V 40 = 400 V
20 = 200 V 42 = 420 V
23 = 230 V 47 = 470 V
25 = 250 V 60 = 600 V
Leads
A = None
B = 0.8 mm
C = 1 mm
Lead Shape
(See Product Dimension Drawings)
Fail-Short Option
Blank = Standard Product
F = With Fail-Short Mechanism
Lead Free Option
Blank = Standard Product
LF = Lead Free/RoHS Compliant Product (Not available on models
with Fail-Short Mechanism)

2036-40-C6F

Mfr. #:
Manufacturer:
Bourns
Description:
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union