RACD150-36-ENEC

Specifications
L-52 www.recom-electronic.com
REV: 0/2013
RACD150-ENEC
LIGHTLINE
AC/DC-Converter
with 5 Year Warranty
150 Watt
Single
Output
Universal AC Input
Constant Voltage / Constant Current Operation
CE and ENEC Certified Class 1 LED Driver
Active Power Factor Correction
IP67 Design for Indoor and Outdoor Use
Cooling by Free Air Convection
Features
LED DRIVER
RoHS
2011/65/EU
6/6
Note:
The use of a circuit breaker with
C-characteristic is recommended.
EN 61347 Certified
EN 62384 Certified
Selection Guide
Part CV Mode CC Mode Efficiency
Constant Voltage Current Range DC Voltage Range Constant Current (230VAC)
(V) (A) (V) (A) (typ.)
RACD150-12-ENEC 12 0-11 9-12 11 88%
RACD150-24-ENEC 24 0-6.3 14-24 6.3 90%
RACD150-36-ENEC 36 0-4.2 26-36 4.2 90%
RACD150-48-ENEC 48 0-3.2 34-48 3.2 90%
Input Voltage Range 90-305 VAC or 127-430VDC
Input Frequency Range 47-63Hz.
Power Factor Full Load, 115VAC >0.98
Full Load, 230VAC >0.95
Full Load, 277VAC >0.94
THD Full Load, 115VAC 8% max.
AC Current 115VAC 2A max.
230VAC 1A max.
Input / Output Isolation 3.75kVAC
Input / Case Isolation 1.8kVAC
Output / Case Isolation 0.5kVAC
Leakage Current 230VAC <0.5mA
Current Tolerance ±5%
Voltage Tolerance -1% to 5%
Set up Time 115VAC 1.0s
(@ Full Load) 230VAC / 277VAC 0.8s
Ripple & Noise 48V Version 200mV max.
others 150mV max.
(with 20MHz bandwidth & 47μF Elco + 0.1μF MLCC)
Over Current Protection 95%-105% rated current Auto-Recovery
Short Circuit Protection Hiccup Mode
Over Voltage Protection 12V 12.5V typ.
Latch Mode 24V 24.5V typ.
(Power off to recover) 36V 36.5V typ.
48V 48.5V typ.
Over Temperature Protection Tcase 95°C ±10°C
Operation Temperature (Refer to Output Load Derating Curve) -30°C to +70°C
Operation Humidity 20%-90% RH Non-Condensing
Storage Temperature -40°C to +80°C
Storage Humidity 10%-90% RH
Vibration 2G 10min/1Cycle, Period for 60 min 10-500Hz
IP Rating IP67
Safety Standards RCM (U21457) AS/NZS 61347.1:2002, IEC 61347-2-13
ENEC General Safety EN 61347-1: 2008
Safety of AC supplied Control Gear for LED Modules EN 61347-2-13: 2006
EMC Standards EMC Compatibility EN55015
FCC, Part 15
Harmonic Current EN61000-3-2 Class C (
75% load)
EN61000-3-3
EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11
continued on next page
www.recom-international.com L-53REV: 0/2013
RACD150
Derating Curve
RACD150-ENEC
Series
LIGHTLINE
AC/DC-Converter
-30 10-10 30 50 70
20%
40%
60%
80%
100%
Load
Ambient Temperature (°C)
90 130100 180 220
300
20%
40%
60%
80%
100%
Load
Input Voltage (VAC) 47-63Hz
240
Ta=25°C
55
115V
230V
0
70%
Characteristics
Package Style and Pinning
Constant Voltage / Constant Current Curve
Vout (max.)
0 20 40 60 80 100 120
Vout (min.)
~0.5V (max.)
Output Current (%)
Output Voltage (%)
3rd angle
projection
Specifications
Dimension 199.2*68*39mm
Weight 1080g
MTBF using MIL-HDBK-217F (25°C) 200 x 10³ hours
Design Lifetime 70 x 10³ hours