https://www.phoenixcontact.com/pi/products/1440782
08/21/2018Page2/4
Sensor/actuator connector-SACC-M12FS-4QO-0,75-VA-1440782
Technical data
General
Insulation resistance ≥ 100 MΩ
Coding A - standard
Standards/regulations M12 connector according to IEC61076-2-101
Signal type/category Universal
Status display No
Overvoltage category II
Degree of pollution 3
Connection method Insulation displacement connection
Conductor cross section 0.34 mm² ... 0.75 mm²
Conductor cross section AWG 22 ... 18
Wire diameter including insulation 1.3 mm ... 2.6 mm
Frequency of connections between conductors of the same cross
section
10
Wire insulation material PVC / PE / PP / rubber
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter Class 2-6
Insertion/withdrawal cycles ≥ 100
Torque 0.4 Nm (M12 knurl)
1.5 Nm (Pressure nut)
Assembly instructions AWG 18 wire cross section upon request
Material
Flammability rating according to UL 94 V0
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material TPU
Material of grip body PA 6
Material, knurls Stainless steel 1.4404
Sealing material Neoprene (Cable clamping)
FPM (M12 socket)
Cable
Standards/specifications M12 connector according to IEC61076-2-101
Standards and Regulations
Standard designation M12 connector
Standards/regulations according to IEC61076-2-101
Flammability rating according to UL 94 V0
Environmental Product Compliance
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings