2325 Orchard Parkway
San Jose, CA 95131
TITLE
DRAWING NO.
R
REV.
1/8/02
COMMON DIMENSIONS
(Unit of Measure = mm)
SYMBOL
MIN
NOM
MAX
NOTE
D 9.60 9.70 9.80 2, 5
E 8.10 BSC
E1 6.00 6.10 6.20 3, 5
A
– –
1.20
A2 0.80 1.00 1.05
b 0.19
–
0.30 4
e 0.65 BSC
L 0.45 0.60 0.75
L1 1.00 REF
28A3, 28-lead, 6.1 x 9.7 mm Body, 0.65 pitch,
Thin Shrink Small Outline Package (TSSOP)
28A3
L1
A
L
D
A2
E
E1
e
b
Top View
Side View
End View
A
1. This drawing is for general information only. Please refer to JEDEC Drawing MO-153, Variation DB for additional
information.
2. Dimension D does not include mold Flash, protrusions or gate burrs. Mold Flash, protrusions and gate burrs shall
not exceed 0.15 mm (0.006 in) per side.
3. Dimension E1 does not include inter-lead Flash or protrusions. Inter-lead Flash and protrusions shall not exceed
0.25 mm (0.010 in) per side.
4. Dimension b does not include Dambar protrusion. Allowable Dambar protrusion shall be 0.08 mm total in excess of
the b dimension at maximum material condition. Dambar cannot be located on the lower radius of the foot. Minimum
space between protrusion and adjacent lead is 0.07 mm.
5. Dimension D and E1 to be determined at Datum Plane H.
Note: