150W Single Output Switching Power Supply
HEP-150 series
File Name:HEP-150-SPEC 2018-01-15
SPECIFICATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.5
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer for A type only
1000ms,50ms/115VAC 500ms,50ms/230VAC at full load
16ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
<0.75mA / 277VAC
105 ~ 125%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level (surge 6KV), criteria A, EAC TP TC 020
-55 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-60 ~ +80 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 60 )
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL60950-1
, EAC TP TC 004, IP65 (or IP68 for HEP-150 Blank type) approved ; design refer to TUV EN60950-1
164.1K hrs min. MIL-HDBK-217F (25 )℃
228*68*38.8mm (L*W*H)
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 28 ~ 34V 41 ~ 46V 54 ~ 63V 59 ~ 65V
91.5% 92% 93% 93.5% 94% 94%
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
7.5 ~ 12.5A 6 ~ 10A 3.8 ~ 6.3A 2.5 ~ 4.2A 1.92 ~ 3.2A 1.68 ~ 2.8A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±0.5% ±0.5% ±0.5% ±0.5%
12V 15V 24V 36V 48V 54V
HEP-150-12 HEP-150-15 HEP-150-24 HEP-150-36 HEP-150-48 HEP-150-54
12.5A 10A 6.3A 4.2A 3.2A 2.8A
150W 150W 151.2W 151.2W 153.6W 151.2W
150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p
10.8 ~ 13.5V 13.5 ~ 17V 22 ~ 27V 33 ~ 40V 43 ~ 53V 49 ~ 58V
EMC IMMUNITY
EMC EMISSION
COLD START 65A at 230VAC
PACKING
1.15Kg; 12pcs/14.8Kg/0.8CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. A type only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that
will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude℃℃
higher than 2000m(6500ft).
SAFETY STANDARDS Note.6,9