MAX6648/MAX6692
Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
4
______________________________________________________________________________________________________________________________________________________________________________
Typical Operating Characteristics
(V
CC
= 3.3V, T
A
= +25°C, unless otherwise noted.)
STANDBY SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX6648/92 toc01
SUPPLY VOLTAGE (V)
STANDBY SUPPLY CURRENT (μA)
5.04.54.03.5
2.8
3.2
3.6
4.0
2.4
3.0 5.5
OPERATING SUPPLY CURRENT
vs. CONVERSION RATE
MAX6648/92 toc02
CONVERSION RATE (Hz)
OPERATING SUPPLY CURRENT (μA)
4.002.001.000.500.250.13
100
200
300
400
500
600
0
0.63
REMOTE TEMPERATURE ERROR
vs. REMOTE-DIODE TEMPERATURE
MAX6648/92 toc03
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
100755025
-1.5
-0.5
0.5
1.5
2.5
-2.5
0125
T
A
= +85°C
FAIRCHILD 2N3906
LOCAL TEMPERATURE ERROR
vs. DIE TEMPERATURE
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
1.0
-1.0
MAX6648/92 toc05
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
1007550250125
REMOTE TEMPERATURE ERROR
vs. 45nm REMOTE DIODE TEMPERATURE
MAX6648/92 toc04
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
90807060
-4
-2
0
2
4
6
-6
50 100
TEMPERATURE ERROR
vs. POWER-SUPPLY NOISE FREQUENCY
MAX6648/92 toc06
FREQUENCY (Hz)
TEMPERATURE ERROR (°C)
10k1k1 10 100
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0
0.1 100k
LOCAL ERROR
REMOTE ERROR
V
IN
= SQUARE WAVE APPLIED TO V
CC
WITH NO 0.1μF V
CC
CAPACITOR
-1
0
1
2
3
4
5
6
7
8
9
-2
TEMPERATURE ERROR
vs. COMMON-MODE NOISE FREQUENCY
MAX6648/92 toc07
FREQUENCY (Hz)
TEMPERATURE ERROR (°C)
100k10k10 100 1k1
REMOTE ERROR
LOCAL ERROR
V
IN
= AC-COUPLED TO DXN
V
IN
= 100mV
P-P
-1.5
-1.0
-0.5
0
0.5
1.0
1.5
2.0
-2.0
TEMPERATURE ERROR
vs. DIFFERENTIAL-MODE NOISE FREQUENCY
MAX6648/92 toc08
FREQUENCY (Hz)
TEMPERATURE ERROR (°C)
100k10k10 100 1k1
V
IN
= 20mV
P-P
SQUARE WAVE
APPLIED TO DXP-DXN
TEMPERATURE ERROR
vs. DXP-DXN CAPACITANCE
MAX6648/92 toc09
DXP-DXN CAPACITANCE (nF)
TEMPERATURE ERROR (°C)
10.0001.000
-5
-4
-3
-2
-1
0
1
-6
0.100 100.000
MAX6648/MAX6692
Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
______________________________________________________________________________________________________________________________________________________________________________
5
Detailed Description
The MAX6648/MAX6692 are temperature sensors
designed to work in conjunction with a microprocessor
or other intelligence in thermostatic, process-control, or
monitoring applications. Communication with the
MAX6648/MAX6692 occurs through the SMBus-com-
patible serial interface and dedicated alert pins. ALERT
asserts if the measured local or remote temperature is
greater than the software-programmed ALERT high
limit or less than the ALERT low limit. ALERT also
asserts if the remote-sensing diode pins are shorted or
unconnected. The overtemperature alarm, OVERT,
asserts if the software-programmed OVERT limit is
exceeded. OVERT can be connected to fans, a system
shutdown, a clock throttle control, or other thermal-
management circuitry.
The MAX6648/MAX6692 convert temperatures to digital
data either at a programmed rate or in single conver-
sions. Temperature data is represented as 10 bits plus
sign, with the LSB equal to 0.125°C. The “main” tempera-
ture data registers (at addresses 00h and 01h) are 8-bit
registers that represent the data as 7 bits with the final
MSB indicating the diode fault status (Table 1). The
remaining 3 bits of temperature data are available in the
“extended” registers at addresses 11h and 10h (Table 2).
ADC and Multiplexer
The averaging ADC integrates over a 60ms period
(each channel, typically), with excellent noise rejection.
The multiplexer automatically steers bias currents
through the remote and local diodes. The ADC and
associated circuitry measure each diode’s forward volt-
age and compute the temperature based on this volt-
age. Both channels are automatically converted once
the conversion process has started, either in free-run-
ning or single-shot mode. If one of the two channels is
not used, the device still performs both measurements,
and the user can ignore the results of the unused chan-
Pin Description
PIN NAME FUNCTION
1V
CC
Supply Voltage Input, 3V to 5.5V. Bypass V
CC
to GND with a 0.1µF capacitor. A 200Ω series
resistor is recommended but not required for additional noise filtering.
2 DXP
Combined Remote-Diode Current Source and A/D Positive Input for Remote-Diode Channel. DO
NOT LEAVE DXP DISCONNECTED; connect DXP to DXN if no remote diode is used. Place a
2200pF capacitor between DXP and DXN for noise filtering.
3DXN
Combined Remote-Diode Current Sink and A/D Negative Input. DXN is internally biased to one
diode drop above ground.
4 OVERT
Overtemperature Alert/Interrupt Output, Open Drain. OVERT is logic low when the temperature is
above the software-programmed threshold.
5 GND Ground
6 ALERT
SMBus Alert (Interrupt) Output, Open Drain. ALERT asserts when temperature exceeds user-set
limits (high or low temperature). ALERT stays asserted until acknowledged by either reading the
status register or by successfully responding to an alert response address, provided that the fault
condition no longer exists. See the
ALERT
Interrupts section.
7 SDA SMBus Serial-Data Input/Output, Open Drain
8 SCLK SMBus Serial-Clock Input
TEMP (°C) DIGITAL OUTPUT
130 0 111 1111
127 0 111 1111
126 0 111 1111
25 0 001 1001
0 0 000 0000
<0 0 000 0000
-1 0 000 0000
-25 0 000 0000
Diode fault
(short or open)
1 000 0000
Table 1. Main Temperature Data Register
Format (00h, 01h)
MAX6648/MAX6692
nel. If the remote-diode channel is unused, connect
DXP to DXN rather than leaving the pins open.
The DXN input is biased to one V
BE
above ground by
an internal diode to prepare the ADC inputs for a differ-
ential measurement. The worst-case DXP-DXN differen-
tial input voltage range is 0.25V to 0.95V. Excess
resistance in series with the remote diode causes
+0.5°C (typ) error per ohm.
A/D Conversion Sequence
A conversion sequence consists of a local temperature
measurement and a remote temperature measurement.
Each time a conversion begins, whether initiated auto-
matically in the free-running autonomous mode (RUN = 0)
or by writing a one-shot command, both channels are
converted, and the results of both measurements are
available after the end of a conversion. A BUSY status bit
in the status byte indicates that the device is performing a
new conversion. The results of the previous conversion
are always available, even if the ADC is busy.
Low-Power Standby Mode
Standby mode reduces the supply current to less than
10µA by disabling the ADC and timing circuitry. Enter
standby mode by setting the RUN bit to 1 in the configu-
ration byte register (Table 6). All data is retained in mem-
ory, and the SMBus interface is active and listening for
SMBus commands. Standby mode is not a shutdown
mode. With activity on the SMBus, the device draws more
supply current (see
Typical Operating Characteristics
). In
standby mode, the MAX6648/MAX6692 can be forced to
perform A/D conversions through the one-shot command,
regardless of the RUN bit status.
If a standby command is received while a conversion is
in progress, the conversion cycle is truncated, and the
data from that conversion is not latched into a tempera-
ture register. The previous data is not changed and
remains available.
Supply-current drain during the 125ms conversion peri-
od is 500µA (typ). Slowing down the conversion rate
reduces the average supply current (see
Typical
Operating Characteristics
). Between conversions, the
conversion rate timer consumes about 25µA of supply
current. In standby mode, supply current drops to
about 3µA.
SMBus Digital Interface
From a software perspective, the MAX6648/MAX6692
appear as a set of byte-wide registers that contain tem-
perature data, alarm threshold values, and control bits.
A standard SMBus-compatible 2-wire serial interface is
used to read temperature data and write control bits
and alarm threshold data. These devices respond to the
same SMBus slave address for access to all functions.
The MAX6648/MAX6692 employ four standard SMBus
protocols: write byte, read byte, send byte, and receive
byte (Figures 1, 2, and 3). The shorter receive byte proto-
col allows quicker transfers, provided that the correct
data register was previously selected by a read byte
instruction. Use caution when using the shorter protocols
in multimaster systems, as a second master could over-
write the command byte without informing the first master.
Temperature data can be read from the read internal
temperature (00h) and read external temperature (01h)
registers. The temperature data format for these regis-
ters is 7 bits plus 1 bit, indicating the diode fault status
for each channel, with the LSB representing 1°C (Table
1). The MSB is transmitted first.
An additional 3 bits can be read from the read external
extended temperature register (10h), which extends the
data to 10 bits plus sign and the resolution to 0.125°C
per LSB (Table 2). An additional 3 bits can be read
from the read internal extended temperature register
(11h), which extends the data to 10 bits (plus 1 bit indi-
cating the diode fault status) and the resolution to
0.125°C per LSB (Table 2).
When a conversion is complete, the main temperature
register and the extended temperature register are
updated simultaneously. Ensure that no conversions
are completed between reading the main register and
the extended register, so that both registers contain the
result of the same conversion.
To ensure valid extended data, read extended resolu-
tion temperature data using one of the following
approaches:
1) Put the MAX6648/MAX6692 into standby mode by
setting bit 6 of the configuration register to 1. Initiate
a one-shot conversion using command byte 0Fh.
When this conversion is complete, read the contents
of the temperature data registers.
Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
6
______________________________________________________________________________________________________________________________________________________________________________
FRACTIONAL TEMP (°C) DIGITAL OUTPUT
0.000 000X XXXX
0.125 001X XXXX
0.250 010X XXXX
0.375 011X XXXX
0.500 100X XXXX
0.625 101X XXXX
0.750 110X XXXX
0.875 111X XXXX
Table 2. Extended Resolution Temperature
Register Data Format (10h, 11h)

MAX6692MUA+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Board Mount Temperature Sensors Remote/Local Temperature Sensor