DG408L, DG409L
www.vishay.com
Vishay Siliconix
S16-0276-Rev. J, 22-Feb-16
4
Document Number: 71342
For technical questions, contact: analogswitchsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Notes
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25 °C, full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this datasheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
g. R
DS(on)
= R
DS(on)
max. - R
DS(on)
min.
h. Worst case isolation occurs on channel 4 do to proximity to the drain pin.
i. R
DS(on)
flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
SPECIFICATIONS (Dual Supply V+ = 5 V, V - = -5 V)
PARAMETER SYMBOL
TEST CONDITIONS
UNLESS OTHERWISE
SPECIFIED
V+ = 5 V, ± 10 %, V- = -5 V
V
EN
= 0.6 V or 2.4 V
f
TEMP.
b
TYP.
d
A SUFFIX
-55 °C to +125 °C
D SUFFIX
-40 °C to +85 °C
UNIT
MIN.
c
MAX.
c
MIN.
c
MAX.
c
Analog Switch
Analog Signal Range
e
V
ANALOG
Full - -5 5 -5 5 V
Drain-Source
On-Resistance
R
DS(on)
V
D
= ± 3.5 V, I
S
= 10 mA,
sequence each switch on
Room 20 - 40 - 40
Full - - 50 - 50
Switch Off Leakage
Current
a
I
S(off)
V+ = 5.5, V- = 5.5 V
V
EN
= 0 V, V
D
= ± 4.5 V,
V
S
= ± 4.5 V
Room - -1 1 -1 1
nA
Full - -15 15 -10 10
I
D(off)
Room - -1 1 -1 1
Full - -15 15 -10 10
Channel On Leakage
Current
a
I
D(on)
V+ = 5.5 V, V- = -5.5 V,
V
EN
= 2.4 V, V
D
= ± 4.5 V,
V
S
= ± 4.5 V
Room - -1 1 -1 1
Full - -15 15 -10 10
Digital Control
Logic High Input Voltage V
INH
Full-2.4-2.4-
V
Logic Low Input Voltage V
INL
Full - - 0.6 - 0.6
Input Current
a
I
IN
V
AX
= V
EN
= 2.4 V or 0.6 V Full - -1.5 1.5 -1 1 μA
Dynamic Characteristics
Transition Time
e
t
TRANS
V
S1
= 3.5 V, V
S8
= 0 V, (DG408L)
V
S1b
= 3.5 V, V
S4b
= 0 V, (DG409L)
see figure 2
Room 30 - 60 - 60
ns
Full - - 78 - 65
Break-Before-Make Time
e
t
OPEN
V
S(all)
= V
DA
= 3.5 V,
see figure 4
Room 8 1 - 1 -
Full-----
Enable Turn-On Time
e
t
ON(EN)
V
AX
= 0 V, V
S1
= 3.5 V (DG408L)
V
AX
= 0 V, V
S1b
= 3.5 V (DG409L)
see figure 3
Room 25 - 55 - 55
Full - - 68 - 60
Enable Turn-Off Time
e
t
OFF(EN)
Room 20 - 40 - 40
Full - - 50 - 45
Source Off Capacitance
e
C
S(off)
f = 1 MHz, V
S
= 0 V, V
EN
= 0 VRoom6----
pFDrain Off Capacitance
e
C
D(off)
f = 1 MHz, V
D
= 0 V, V
EN
= 0 VRoom15----
Drain On Capacitance
e
C
D(on)
f = 1 MHz, V
D
= 0 V, V
EN
= 2.4 VRoom29----
DG408L, DG409L
www.vishay.com
Vishay Siliconix
S16-0276-Rev. J, 22-Feb-16
5
Document Number: 71342
For technical questions, contact: analogswitchsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Notes
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25 °C, full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
g. R
DS(on)
= R
DS(on)
max. - R
DS(on)
min.
h. Worst case isolation occurs on channel 4 do to proximity to the drain pin.
i. R
DS(on)
flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
SPECIFICATIONS (Single Supply 5 V)
PARAMETER SYMBOL
TEST CONDITIONS
UNLESS OTHERWISE
SPECIFIED
V+ = 5 V, ± 10 %, V- = 0 V
V
EN
= 0.6 V or 2.4 V
f
TEMP.
b
TYP.
d
A SUFFIX
-55 °C to +125 °C
D SUFFIX
-40 °C to +85 °C
UNIT
MIN.
c
MAX.
c
MIN.
c
MAX.
c
Analog Switch
Analog Signal Range
e
V
ANALOG
Full - 0 5 0 5 V
Drain-Source
On-Resistance
R
DS(on)
V+ = 4.5 V, V
D
or V
S
= 1 V or 3.5 V,
I
S
= 5 mA
Room 35 - 49 - 40
Full - - 62 - 62
R
DS(on)
Matching Between
Channels
g
R
DS
V+ = 4.5 V, V
D
= 1 V or 3.5 V,
I
S
= 5 mA
Room 1.5 - 3 - 3
On-Resistance Flatness
i
R
FLAT(on)
Room - - 4 - 4
Switch Off Leakage
Current
a
I
S(off)
V+ = 5.5 V, V
S
= 1 V or 4 V,
V
D
= 4 V or 1 V
Room - -1 1 -1 1
nA
Full - -15 15 -10 10
I
D(off)
Room - -1 1 -1 1
Full - -15 15 -10 10
Channel On Leakage
Current
a
I
D(on)
V+ = 5.5 V, V
D
= V
S
= 1 V or 4 V,
sequence each switch on
Room - -1 1 -1 1
Full - -15 15 -10 10
Digital Control
Logic High Input Voltage V
INH
V+ = 5 V
Full-2.4-2.4-
V
Logic Low Input Voltage V
INL
Full - - 0.6 - 0.6
Input Current
a
I
IN
V
AX
= V
EN
= 2.4 V or 0.6 V Full - -1.5 1.5 -1 1 μA
Dynamic Characteristics
Transition Time
e
t
TRANS
V
S1
= 3.5 V, V
S8
= 0 V, (DG408L)
V
S1b
= 3.5 V, V
S4b
= 0 V, (DG409L)
see figure 2
Room 44 - 125 - 125
ns
Full - - 138 - 135
Break-Before-Make Time
e
t
OPEN
V
S(all)
= V
DA
= 3.5 V,
see figure 4
Room 17 1 - 1 -
Full-----
Enable Turn-On Time
e
t
ON(EN)
V
AX
= 0 V, V
S1
= 3.5 V (DG408L)
V
AX
= 0 V, V
S1b
= 3.5 V (DG409L)
see figure 3
Room 43 - 60 - 60
Full - - 70 - 65
Enable Turn-Off Time
e
t
OFF(EN)
Room 26 - 45 - 45
Full - - 60 - 50
Charge Injection
e
Q
C
L
= 1 nF, R
GEN
= 0 ,
V
GEN
= 0 V
Room-1----pC
Off Isolation
e, h
OIRR
f = 100 kHz, R
L
= 1 k
Room-70----
dB
Crosstalk
e
X
TALK
Room-80----
Source Off Capacitance
e
C
S(off)
f = 1 MHz, V
S
= 0 V, V
EN
= 0 VRoom8----
pFDrain Off Capacitance
e
C
D(off)
f = 1 MHz, V
D
= 0 V, V
EN
= 0 VRoom21----
Drain On Capacitance
e
C
D(on)
f = 1 MHz, V
D
= 0 V, V
EN
= 2.4 VRoom32----
DG408L, DG409L
www.vishay.com
Vishay Siliconix
S16-0276-Rev. J, 22-Feb-16
6
Document Number: 71342
For technical questions, contact: analogswitchsupport@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Notes
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25 °C, full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
g. R
DS(on)
= R
DS(on)
max. - R
DS(on)
min.
h. Worst case isolation occurs on channel 4 do to proximity to the drain pin.
i. R
DS(on)
flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONS (Single Supply 3 V)
PARAMETER SYMBOL
TEST CONDITIONS
UNLESS OTHERWISE
SPECIFIED
V+ = 3 V, ± 10 %, V- = 0 V
V
EN
= 0.4 V or 2 V
f
TEMP.
b
TYP.
d
A SUFFIX
-55 °C to +125 °C
D SUFFIX
-40 °C to +85 °C
UNIT
MIN.
c
MAX.
c
MIN.
c
MAX.
c
Analog Switch
Analog Signal Range
e
V
ANALOG
Full - 0 3 0 3 V
Drain-Source
On-Resistance
R
DS(on)
V+ = 2.7 V, V
D
= 0.5 or 2.2 V,
I
S
= 5 mA
Room 60 - 80 - 80
Full - - 105 - 100
Switch Off Leakage
Current
a
I
S(off)
V+ = 3.3 V, V
S
= 2 or 1 V,
V
D
= 1 or 2 V
Room - -1 1 -1 1
nA
Full - -15 15 -10 10
I
D(off)
Room - -1 1 -1 1
Full - -15 15 -10 10
Channel On Leakage
Current
a
I
D(on)
V+ = 3.3 V, V
D
= V
S
= 1 V or 2 V,
sequence each switch on
Room - -1 1 -1 1
Full - -15 15 -10 10
Digital Control
Logic High Input Voltage V
INH
Full - 2 - 2 -
V
Logic Low Input Voltage V
INL
Full - - 0.4 - 0.4
Input Current
a
I
IN
V
AX
= V
EN
= 2.4 V or 0.4 V Full - -1.5 1.5 -1 1 μA
Dynamic Characteristics
Transition Time t
TRANS
V
S1
= 1.5 V, V
S8
= 0 V, (DG408L)
V
S1b
= 1.5 V, V
S4b
= 0 V, (DG409L)
see figure 2
Room 75 - 150 - 150
ns
Full - - 175 - 175
Break-Before-Make Time t
OPEN
V
S(all)
= V
DA
= 1.5 V,
see figure 4
Room 32 1 - 1 -
Full-----
Enable Turn-On Time t
ON(EN)
V
AX
= 0 V, V
S1
= 1.5 V (DG408L)
V
AX
= 0 V, V
S1b
= 1.5 V (DG409L)
see figure 3
Room 70 - 95 - 95
Full - - 115 - 105
Enable Turn-Off Time t
OFF(EN)
Room 55 - 100 - 100
Full - - 115 - 105
Charge Injection
e
Q
C
L
= 1 nF, R
GEN
= 0 ,
V
GEN
= 1.5 V
Room0.4----pC
Off Isolation
e, h
OIRR
f = 100 kHz, R
L
= 50
Room-70----
dB
Crosstalk
e
X
TALK
Room-79----
Source Off Capacitance
e
C
S(off)
f = 1 MHz, V
S
= 0 V, V
EN
= 0 VRoom8----
pF
Drain Off Capacitance
e
C
D(off)
f = 1 MHz, V
D
= 0 V, V
EN
= 0 VRoom19----
Drain On Capacitance
e
C
D(on)
f = 1 MHz, V
D
= 0 V, V
EN
= 2 V
(DG409L only)
Room33----

DG408LDY-T1-E3

Mfr. #:
Manufacturer:
Vishay
Description:
Multiplexer Switch ICs LV Single 8:1 3-bit Multiplexer/MUX
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: