ALA2F12

–1–
ASCTB191E 201605-T
ORDERING INFORMATION
TYPES
Standard packing Carton: 100 pcs. Case: 500 pcs.
Note: 4.5V, 5V, 6V, 9V and 18V DC types are also available. Please consult us for details.
TV-4 rated.
2 Form A 3A/5A
power relays
LA RELAYS (ALA)
Contact arrangement Coil voltage
Part No.
3A type 5A TV type (TV-4)
2 Form A
12V DC ALA2F12 ALA2PF12
24V DC ALA2F24 ALA2PF24
Protective construction: Flux-resistant
type
RoHS compliant
FEATURES
1. 2 Form A slim type
24(L) × 12(W) × 25(H) mm
.945(L)×.472(W)×.984(H) inch
2. 3A type and 5A TV type
3A type: Contact reliability and break
performance best suited for protecting
and switching speakers.
5A TV type: Tough against inrush current
and optimal for turning on and off the
power supply. Rated TV-4 (UL, CSA).
3. Long insulation distance
• Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
• Surge withstand voltage between
contact and coil: 10,000 V
4. High noise immunity realized by the
card separation structure between
contact and coil
5. Conforms to the various safety
standards
• UL, CSA, VDE, TÜV, SEMKO approved
TYPICAL APPLICATIONS
• Audio devices
• Monitor
• Automatic vending machine
LA relay
ALA 2 F
Contact capacity
Nil:
P:
3A
5A TV-4
Protective construction
F: Flux-resistant type
Nominal coil voltage (DC)
12: 12V, 24: 24V
Contact arrangement
2: 2 Form A
Note: Certified by UL, CSA, VDE, TÜV, SEMKO and TV-4
LA (ALA2)
–2–
ASCTB191E 201605-T
RATING
1. Coil data
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
12V DC
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
44.2mA 272Ω
530mW
15.6V DC
24V DC 22.1mA 1,087Ω 31.2V DC
Characteristics Item
Specifications
3A type 5A TV type (TV-4)
Contact
Arrangement 2 Form A
Contact resistance (Initial) Max. 50 mΩ (By voltage drop 6V DC 1A) Max. 100 mΩ (By voltage drop 6V DC 1A)
Contact material Gold-clad, AgNi type AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 3A 125V AC 5A 277V AC
Max. switching power (resistive load) 625VA 1,385VA
Max. switching voltage 125V AC 277V AC
Max. switching current 5A (AC)
Min. switching capacity (reference value)*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between contact sets 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 15 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 15 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 10
6
(at 180 times/min.)
Electrical (at 20 times/min.) Min. 5×10
4
(ON: OFF=1.5s: 1.5s) (at nominal switching capacity)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 13 g .46 oz
1. Max. switching power (AC resistive load) 2-(1). Life curve (250 V AC resistive load)
3A type (ALA2F)
2-(2). Life curve (125 V AC resistive load)
5A TV type (ALA2PF)
10
3
5
0 300100
Contact voltage, V
Contact current, A
5A TV type (ALA2PF)
3A type (ALA2F)
100
10
1
10 2345
250V AC resistive load
Contact current, A
Life, ×10
4
100
10
1
1023
125V AC resistive load
Contact current, A
Life, ×10
4
LA (ALA2)
–3–
ASCTB191E 201605-T
3-(1). Coil temperature rise
Sample: ALA2F12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 3A
3-(2). Coil temperature rise
Sample: ALA2PF12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 5A
4. Ambient temperature characteristics and coil
applied voltage
Contact current: ALA2F=3A
ALA2PF=5A
800
0
5
10
15
20
25
30
35
40
45
50
100 120
Temperature rise, °C
Coil applied voltage, %V
20°C 3A
20°C 0A
70°C 3A
70°C 0A
800
0
5
10
15
20
25
30
35
40
45
50
100 120
Temperature rise, °C
Coil applied voltage, %V
70°C 5A
70°C 0A
20°C 5A
20°C 0A
0
200
100
50
150
020406080
Ambient temperature, °C
Allowable ambient temperatures
against % coil voltages
(max. inside the coil
temperature set as
115°C
Coil applied voltage, %V
239°F)
5-(1). Electrical life test
(3 A 125 V AC, resistive load)
Sample: ALA2F12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
G
NO
COM
NO
COM
125V AC
12V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
0
0
20
40
60
80
100
2.5 5
Max.
Min.
x
Max.
Min.
x
No. of operations, ×10
4
Pick-up and drop-out voltage, %V
Pick-up voltage
Drop-out voltage
0
0
10
20
30
40
50
52.5
Max.
Min.
x
No. of operations, ×10
4
Contact resistance, mΩ
5-(2). Electrical life test
(5 A 250 V AC, resistive load)
Sample: ALA2PF12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C 68°F
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
G
NO
COM
NO
COM
250V AC
12V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
0
0
20
40
60
80
100
2.5 5
Max.
Min.
x
Max.
Min.
x
No. of operations, ×10
4
Pick-up and drop-out voltage, %V
Pick-up voltage
Drop-out voltage
0
0
10
20
30
40
50
52.5
Max.
Min.
x
No. of operations, ×10
4
Contact resistance, mΩ
5-(3). Electrical life test
(UL lamp load test TV-4)
Tested sample: ALA2PF12, 6 pcs.
• Overload test
Load: 6.0 A 120 V AC (60 Hz),
Inrush: 91 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
• Endurance test
Load: 4A 120 V AC (60 Hz),
Inrush: 65 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
Change of pick-up and drop-out voltage Change of contact resistance
0
0
20
40
60
80
100
2.5
Max.
Min.
x
Max.
Min.
x
No. of operations, ×10
4
Pick-up and drop-out voltage, %V
Pick-up voltage
Drop-out voltage
0
0
10
20
30
40
50
2.5
Max.
Min.
x
No. of operations, ×10
4
Contact resistance, mΩ

ALA2F12

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays 2 Form A 3A 125VAC 12VDC l
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union