Surge arrester B88069X0660S102
2-electrode arrester EC230X
PPD AB PD / PPD AB PM Issue 09 / 2015-01-13
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.
Features Applications
Standard size
Very fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Branch exchange
Line protection
Subscriber protection
Alarm system
Tuner
Antenna protection
Electrical specifications
DC spark-over voltage
1) 2)
Tolerance
Min.
Max.
230
±15
196
264
V
%
V
V
Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs - for 99% of measured values
- typical values of distribution
< 550
< 500
< 700
< 650
V
V
V
V
Service life
10 operations 50 Hz, 1 s 5 A
1 operation 50 Hz, 0.18 s (9 cycles) 20 A
10 operations 8/20 µs 5 kA
1 operation 8/20 µs 10 kA
3 operations 8/20 µs 10 kA
1 operation 10/350 µs 1 kA
Insulation resistance at 100 V
DC
> 10
G
Capacitance at 1 MHz < 1.5
pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 12
< 0.5
~ 60
V
A
V
Weight ~ 1.5 g
Operation and storage temperature
40 ... +90
°C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red positive
EC 230 YY O
EC - Series
230 - Nominal voltage
YY - Year of production
O - Non radioactive
Certification UL 497B (E163070)
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.