C4C-SA03030A10000

A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
C4C-SA03030A10000 | deTec
SAFETY LIGHT CURTAINS
Dimensional drawing (Dimensions in mm (inch))
34
(1.34)
30
(1.18)
30.7
(1.21)
1
4
2
5
3
5
(0.2)
4
(0.16)
14
(0.55)
56.8
(2.24)
56.8
(2.24)
56.8
(2.24)
L
L
29.5
(1.16)
30.7
(1.21)
7
(0.28)
12
(0.47)
6.3
(0.25)
L=150 (5.91)
13
(0.51)
13.8
(0.54)
21.1
(0.83)
21.8
(0.86)
106.8
(4.2)
L
300 313
450 463
600 613
750 763
900 913
1,050 1,063
1,200 1,213
1,350 1,362
1,500 1,512
1,650 1,662
1,800 1,812
1,950 1,962
2,100 2112
4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-07-30 19:28:32
Subject to change without notice
C4C-SA03030A10000 | deTec
SAFETY LIGHT CURTAINS
Connection diagram
deTec4 Core safety light curtain to UE48-2OS safety relay
S34 S21S35 S22
S33 S12S11 S31
14A2 24 32
13A1 23 31
UE48-2OS2D2
K1 K2
S1
k1
k2
OSSD1
OSSD2
n.c.
GND
+24V
1
2
3
4
5
+24V
n.c.
GND
n.c.
n.c.
1
2
3
4
5
24 V DC
0 V DC
E114585/01/2014-05-08
Task
Connection of a deTec4 Core safety light curtain to a UE48-2OS.
Operating mode: With restart interlock and external device monitoring
Mode of operation
When the light path is clear, the OSSD1 and OSSD2 outputs carry voltage. When K1 and K2 are in a fault-free de-energized posi-
tion, the system can be switched on and waits for an input signal/switch-on signal. The UE48-2OS is switched on by pressing and
then releasing the S1 pushbutton. The outputs (contacts 13- 14and 23- 24) switch the K1 and K2 contactors on. When one or
more light beams are interrupted, the OSSD1 and OSSD2 outputs switch off the UE48-2OS. Contactors K1 and K2 are switched
off.
Fault analysis
Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). A malfunction with one of the
K1 or K2 contactors is detected. The shut-down function is retained. In the event of manipulation (e.g., jamming) of the S1 push-
button, the UE48-2OS will not re-enable the output current circuits.
Comments
1)
Output circuits: These contacts must be incorporated into the control such that the dangerous state is brought to an end if the
output circuit is open. For categories 4and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation
into the control (z path) is only possible with a single-channel control and taking the risk analysis into account.
2018-07-30 19:28:32 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
C4C-SA03030A10000 | deTec
SAFETY LIGHT CURTAINS
Recommended accessories
Other models and accessories www.sick.com/deTec
Brief description Type Part no.
Adapters and distributors
T-piece for simultaneous connection to sender and receiver, splits the cable from the
control cabinet to the sender and receiver
DSC-1205T000025KM0 6030664
Plug connectors and cables
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 2m
YF2A15-020UB5XLEAX 2095617
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 5m
YF2A15-050UB5XLEAX 2095618
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 10m
YF2A15-100UB5XLEAX 2095619
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 20m
YF2A15-200UB5XLEAX 2095614
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 30m
YF2A15-300UB5XLEAX 2095621
Head A: female connector, M12, 5-pin, angled, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 2m
YG2A15-020UB5XLEAX 2095772
Head A: female connector, M12, 5-pin, angled, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 5m
YG2A15-050UB5XLEAX 2095773
Head A: female connector, M12, 5-pin, angled, A-coded
Head B: Flying leads
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 10m
YG2A15-100UB5XLEAX 2095774
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: male connector, M12, 5-pin, straight, A-coded
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 5m
YF2A15-050UB5M2A15 2096010
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: male connector, M12, 5-pin, straight, A-coded
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 10m
YF2A15-100UB5M2A15 2096011
Head A: female connector, M12, 5-pin, straight, A-coded
Head B: male connector, M12, 5-pin, straight, A-coded
Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 15m
YF2A15-150UB5M2A15 2096171
Test and monitoring tools
30mm diameter Test rod 30mm 2022602
6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-07-30 19:28:32
Subject to change without notice

C4C-SA03030A10000

Mfr. #:
Manufacturer:
Description:
Safety Light Curtain, deTec4 Core, ProtHeight:300 mm, Male Conn M12, 5-pin
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union