IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (OPTION 060)
Description Symbol
Characteristic HCPL-
Unit2530/2531/4534 0530/0531/0534
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – IV
I – IV
I – IV
I – IV
I – III
Climatic Classication 0/70/21 0/70/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 567 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test
t
m
=1 sec, Partial discharge < 5 pC
V
PR
1181 1063 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test,
t
m
=10 sec, Partial discharge < 5 pC
V
PR
1008 907 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 60 sec) V
IOTM
8000 6000 V
peak
Safety-limiting values – max. values allowed in the event of a failure.
Case Temperature
Input Current**
Output Power**
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
150
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
>10
9
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer's Catalog, under Product Safety Regulations section,
IEC/EN/DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test proles.
** Refer to the following gure for dependence of P
S
and I
S
on ambient temperature.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.